The DOI matches its Crossref record.
In vitro MC3T3 osteoblast adhesion with respect to surface roughness of Ti6Al4V substrates
Abstract
This work investigates the role of the surface roughness of Ti6Al4V on the cell morphology, proliferation and adhesion, and in particular on the variation of the expression of cell adhesion proteins. Standardised test samples with five different surface preparations are used: sandblasted, 80, 1200, and 4000 grade polished, mirror polished. Surface roughness is analysed by Scanning Electron Microscopy and LASER Confocal Microscopy. Cell culture experiments are performed with MC3T3-E1 mouse osteoblasts after 3 days culture: proliferation rate, morphology and adhesion are assessed. The variations of expression of cell adhesion proteins are evidenced by indirect immune fluorescence method: actin from the cytoskeleton, vinculin from the focal adhesion complex, fibronectin and collagen I from the extracellular matrix. The results reveal a clear influence of surface roughness of Ti6Al4V on cell proliferation, morphology and adhesion. A significant correlation is established between surface roughness and cell growth. More the surface is smooth more the osteoblasts proliferate and appear spread out on the test samples. In addition, the expression of adhesion proteins varies with respect to the surface roughness. These results indicate a direct relationship between the decrease of cell adhesion and the increase of cell proliferation on mirror polished materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Paital, S. R., & Dahotre, N. B. (2009) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2009.05.001 · Cited by 673
Kim, H.-W., Kim, H.-E., & Salih, V. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.01.047 · Cited by 471
Simchi, A., Tamjid, E., Pishbin, F., & Boccaccini, A. R. (2011) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2010.10.005 · Cited by 404
Peter, M., Ganesh, N., Selvamurugan, N., Nair, S. V., Furuike, T., Tamura, H., & Jayakumar, R. (2010) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2009.11.050 · Cited by 373
Metadata
- Authors
- Linez-Bataillon, P., Monchau, F., Bigerelle, M., & Hildebrand, H. F.
- Venue
- Biomolecular Engineering
- Publisher
- Elsevier BV
- Published
- 2002-08
- Volume
- 19
- Issue
- 2-6
- Pages
- 133-141
- ISSN
- 1389-0344 (ISSN-L)
- OpenAlex
- W2093738019
- Cited by
- 216
- References
- 0
- FWCI
- 8.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro MC3T3 osteoblast adhesion with respect to surface roughness of Ti6Al4V substrates. https://app.cochat.ai/papers/10.1016/s1389-0344(02)00024-2
- The paper
- Linez-Bataillon, P., Monchau, F., Bigerelle, M., & Hildebrand, H. F. (2002). In vitro MC3T3 osteoblast adhesion with respect to surface roughness of Ti6Al4V substrates. Biomolecular Engineering. https://doi.org/10.1016/s1389-0344(02)00024-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.