CoChat

Novel PVC Membrane Based Alizarin Sensor and its application; Determination of Vanadium, Zirconium and Molybdenum

Open access
Gupta, Vinod K., Goyal, Rajendra N., Sharma, Ram A. · 2009 · International Journal of Electrochemical Science
Cited by 184

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

A fabrication of new potentiometric alizarin sensor based on the use of alizarin Red-S-CTAB (ARS-CTAB) ion pair, in poly (vinyl chloride) (PVC) matrix, is reported. Effect of various plasticizers (o-NPOE, DBP, DEP, DOP, TBP, & CN) and cation excluder, Cetryltrimethylammoniumbromide (CTAB) was studied. The best performance was obtained with a membrane composition of PVC: o-NPOE: ARS-CTAB: CTAB ratio (w/w; %) of 31:60:7:2. The sensor exhibits significantly enhanced selectivity towards alizarin over the concentration range 1.0 × 10-8 to 1.0 × 10-3 M with a lower detection limit of 3.0 × 10-9 M and a Nernstian slope of 59.8 mV decade−1 of activity. Influence of the membrane composition, and possible interfering ions was investigated on the response properties of the electrode. Fast and stable response, good reproducibility and long-term stability are demonstrated. The sensor shows response time of < 10 s and can be used for about 3 months without any considerable divergence in their potential response. Selectivity coefficients determined with matched potential method (MPM) indicate high selectivity for alizarin. The proposed electrode shows fairly good discrimination of alizarin from anions. It was successfully applied to determination of vanadium ion in water and soil samples, zirconium ion in alloy samples and molybdenum ion in geological samples using indirect potensiometry and the results obtained are comparable with those provided by AAS analysis. The electrode can be used in the pH range of 2.0 to 5.0 and mixtures containing up to 20% (v/v) non-aqueous content. It was used as an indicator electrode in potentiometric titration of alizarin against EDTA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1452-3981(23)15144-3

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 184

Metadata

Authors
Gupta, V. K., Goyal, R. N., & Sharma, R. A.
Venue
International Journal of Electrochemical Science
Publisher
Elsevier BV
Published
2009-01
Volume
4
Issue
1
Pages
156-172
ISSN
1452-3981 (ISSN-L)
OpenAlex
W2468661901
Cited by
184
References
7
FWCI
26.06
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.