Novel PVC Membrane Based Alizarin Sensor and its application; Determination of Vanadium, Zirconium and Molybdenum
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A fabrication of new potentiometric alizarin sensor based on the use of alizarin Red-S-CTAB (ARS-CTAB) ion pair, in poly (vinyl chloride) (PVC) matrix, is reported. Effect of various plasticizers (o-NPOE, DBP, DEP, DOP, TBP, & CN) and cation excluder, Cetryltrimethylammoniumbromide (CTAB) was studied. The best performance was obtained with a membrane composition of PVC: o-NPOE: ARS-CTAB: CTAB ratio (w/w; %) of 31:60:7:2. The sensor exhibits significantly enhanced selectivity towards alizarin over the concentration range 1.0 × 10-8 to 1.0 × 10-3 M with a lower detection limit of 3.0 × 10-9 M and a Nernstian slope of 59.8 mV decade−1 of activity. Influence of the membrane composition, and possible interfering ions was investigated on the response properties of the electrode. Fast and stable response, good reproducibility and long-term stability are demonstrated. The sensor shows response time of < 10 s and can be used for about 3 months without any considerable divergence in their potential response. Selectivity coefficients determined with matched potential method (MPM) indicate high selectivity for alizarin. The proposed electrode shows fairly good discrimination of alizarin from anions. It was successfully applied to determination of vanadium ion in water and soil samples, zirconium ion in alloy samples and molybdenum ion in geological samples using indirect potensiometry and the results obtained are comparable with those provided by AAS analysis. The electrode can be used in the pH range of 2.0 to 5.0 and mixtures containing up to 20% (v/v) non-aqueous content. It was used as an indicator electrode in potentiometric titration of alizarin against EDTA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackson, M. T. (2014) · Andalas University Repository (Andalas University) · Cited by 15,111
Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics
Bakker, E., Bühlmann, P., & Pretsch, E. (1997) · Chemical Reviews · doi:10.1021/cr940394a · Cited by 2,369
Meier, P. C. (1982) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)95397-8 · Cited by 417
Anion recognition through modified calixarenes: a highly selective sensor for monohydrogen phosphate
Gupta, V. K., Ludwig, R., & Agarwal, S. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.02.008 · Cited by 180
Self-citationAnion recognition through novel C-thiophenecalix[4]resorcinarene: PVC based sensor for chromate ions
Jain, A. K., Gupta, V. K., Singh, L. P., SRIVASTAVA, P., & Raisoni, J. R. (2004) · Talanta · doi:10.1016/j.talanta.2004.07.041 · Cited by 155
Self-citationTelting‐Diaz, M., & Bakker, E. (2001) · Analytical Chemistry · doi:10.1021/ac010526h · Cited by 146
Anion Selective Potentiometric Sensor Based on Gallium Nitride Crystalline Membrane
Alifragis, Y., Konstantinidis, G., Georgakilas, A., & Chaniotakis, N. A. (2005) · Electroanalysis · doi:10.1002/elan.200403191 · Cited by 31
Cited by
Saleh, T. A., & Gupta, V. K. (2012) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2011.12.038 · Cited by 962
Self-citationSorption of pollutants by porous carbon, carbon nanotubes and fullerene- An overview
Gupta, V. K., & Saleh, T. A. (2013) · Environmental Science and Pollution Research · doi:10.1007/s11356-013-1524-1 · Cited by 954
Self-citationRemoval of Cu, Zn, and Cd from aqueous solutions by the dairy manure-derived biochar
Xu, X., Cao, X., Zhao, L., Wang, H., Yu, H., & Gao, B. (2013) · Environmental Science and Pollution Research · doi:10.1007/s11356-012-0873-5 · Cited by 610
Electrochemical Analysis of Some Toxic Metals by Ion–Selective Electrodes
Gupta, V. K., Ganjali, M. R., Norouzi, P., Khani, H., Nayak, A., & Agarwal, S. (2011) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2011.589773 · Cited by 580
Self-citationKarthikeyan, S., Gupta, V. K., Boopathy, R., Titus, A., & Sekaran, G. (2012) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2012.06.022 · Cited by 546
Self-citation
Metadata
- Authors
- Gupta, V. K., Goyal, R. N., & Sharma, R. A.
- Venue
- International Journal of Electrochemical Science
- Publisher
- Elsevier BV
- Published
- 2009-01
- Volume
- 4
- Issue
- 1
- Pages
- 156-172
- ISSN
- 1452-3981 (ISSN-L)
- OpenAlex
- W2468661901
- Cited by
- 184
- References
- 7
- FWCI
- 26.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.