Portable normothermic ex-vivo lung perfusion, ventilation, and functional assessment with the Organ Care System on donor lung use for transplantation from extended-criteria donors (EXPAND): a single-arm, pivotal trial
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND Donor lung use for transplantation is the lowest among solid organ tranplants because of several complex and multifactorial reasons; one area that could have a substantial role is the limited capabilities of cold ischaemic storage. The aim of the EXPAND trial was to evaluate the efficacy of normothermic portable Organ Care System (OCS) Lung perfusion and ventilation on donor lung use from extended-criteria donors and donors after circulatory death, which are rarely used. METHODS In this single-arm, pivotal trial done in eight institutions across the USA, Germany, and Belgium, lungs from extended-criteria donors were included if fulfilling one or more of the following criteria: a ratio of partial pressure of arterial oxygen (PaO2) to fractional concentration of oxygen inspired air (FiO2) in the donor lung of 300 mm Hg or less; expected ischaemic time longer than 6 h; donor age 55 years or older; or lungs from donors after circulatory death that were recruited and assessed using OCS Lung. Lungs were transplanted if they showed stability of OCS Lung variables, PaO2:FiO2 was more than 300 mm Hg, and they were accepted by the transplanting surgeon. Patients were adult bilateral lung transplant recipients. The primary efficacy endpoint was a composite of patient survival at day 30 post-transplant and absence of The International Society for Heart & Lung Tranplantation primary-graft dysfunction grade 3 (PGD3) within 72 h post-transplantation, with a prespecified objective performance goal of 65%. The primary analysis population was all transplanted recipients. This trial is registered with ClinicalTrials.gov, number NCT01963780, and is now complete. FINDINGS Between Jan 23, 2014, and Oct 23, 2016, 93 lung pairs were perfused, ventilated, and assessed on the OCS Lung. 12 lungs did not meet OCS transplantation criteria so 81 lungs were suitable for transplantation. Two lungs were excluded for logistical reasons, hence 79 (87%) of eligible lungs were transplanted. The primary endpoint was achieved in 43 (54%) of 79 patients and did not meet the objective performance goal. 35 (44%) of 79 patients had PGD3 within the initial 72 h. 78 (99%) of 79 patients had survived at 30 days post-transplant. The mean number of lung graft-related serious adverse events (respiratory failure and major pulmonary-related infection) was 0·3 events per patient (SD 0·5). INTERPRETATION Despite missing the objective primary endpoint, the portable OCS Lung resulted in 87% donor lung use for transplantation with excellent clinical outcomes. Many lungs declined by other transplant centres were successfully transplanted using this new technology, which implies its use has the potential to increase the number of lung transplants performed worldwide. Whether similar outcomes could be obtained if these lungs were preserved on ice is unknown and remains an area for future research. FUNDING TransMedics Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical risk factors for primary graft dysfunction after lung transplantation
Diamond, J. M., Lee, J. C., Kawut, S. M., Shah, R. J., Localio, A. R., Bellamy, S. L., Lederer, D. J., Cantu, E., Kohl, B. A., Lama, V. N., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201210-1865oc · Cited by 687
OPTN/SRTR 2016 annual data report: lung
Valapour, M., Lehr, C. J., Skeans, M. A., Smith, J. M., Carrico, R., Uccellini, K., Lehman, R., Robinson, A., Israni, A. K., Snyder, J. J., et al. (2018) · American Journal of Transplantation · doi:10.1111/ajt.14562 · Cited by 163
Cited by
Textbook Outcome: Definition and Analysis of a Novel Quality Measure in Lung Transplantation
Halpern, S. E., Moris, D., Gloria, J. N., Shaw, B. I., Haney, J. C., Klapper, J. A., Barbas, A. S., & Hartwig, M. G. (2023) · Annals of Surgery · doi:10.1097/sla.0000000000004916 · Cited by 40
Self-citation
Metadata
- Authors
- Loor, G., Warnecke, G., Villavicencio, M. A., Smith, M. A., Kukreja, J., Ardehali, A., Hartwig, M., Daneshmand, M. A., Hertz, M. I., Huddleston, S., Haverich, A., Madsen, J. C., & Van Raemdonck, D.
- Venue
- The Lancet Respiratory Medicine
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 7
- Issue
- 11
- Pages
- 975-984
- ISSN
- 2213-2600 (ISSN-L)
- OpenAlex
- W2964618350
- Cited by
- 164
- References
- 2
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Portable normothermic ex-vivo lung perfusion, ventilation, and functional assessment with the Organ Care System on donor lung use for transplantation from extended-criteria donors (EXPAND): a single-arm, pivotal trial. https://app.cochat.ai/papers/10.1016/s2213-2600(19)30200-0
- The paper
- Loor, G., Warnecke, G., Villavicencio, M. A., Smith, M. A., Kukreja, J., Ardehali, A., Hartwig, M., Daneshmand, M. A., Hertz, M. I., Huddleston, S., Haverich, A., Madsen, J. C., & Van Raemdonck, D. (2019). Portable normothermic ex-vivo lung perfusion, ventilation, and functional assessment with the Organ Care System on donor lung use for transplantation from extended-criteria donors (EXPAND): a single-arm, pivotal trial. The Lancet Respiratory Medicine. https://doi.org/10.1016/s2213-2600(19)30200-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.