Fully closed-loop insulin delivery in inpatients receiving nutritional support: a two-centre, open-label, randomised controlled trial
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Glucose management is challenging in patients who require nutritional support in hospital. We aimed to assess whether fully closed-loop insulin delivery would improve glycaemic control compared with conventional subcutaneous insulin therapy in inpatients receiving enteral or parenteral nutrition or both. METHODS: We did a two-centre (UK and Switzerland), open-label, randomised controlled trial in adult inpatients receiving enteral or parenteral nutrition (or both) who required subcutaneous insulin therapy. Patients recruited from non-critical care surgical and medical wards were randomly assigned (1:1) using a computer-generated minimisation schedule (stratified by type of nutritional support [parenteral nutrition on or off] and pre-study total daily insulin dose [<50 or ≥50 units]) to receive fully closed-loop insulin delivery with faster-acting insulin aspart (closed-loop group) or conventional subcutaneous insulin therapy (control group) given in accordance with local clinical practice. Continuous glucose monitoring in the control group was masked to patients, ward staff, and investigators. Patients were followed up for a maximum of 15 days or until hospital discharge. The primary endpoint was the proportion of time that sensor glucose concentration was in target range (5·6-10·0 mmol/L), assessed in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT01774565. FINDINGS: Between Feb 8, 2018, and Sept 21, 2018, 90 patients were assessed for eligibility, of whom 43 were enrolled and randomly assigned to the closed-loop group (n=21) or the control group (n=22). The proportion of time that sensor glucose was in the target range was 68·4% [SD 15·5] in the closed-loop group and 36·4% [26·6] in the control group (difference 32·0 percentage points [95% CI 18·5-45·5; p<0·0001]). One serious adverse event occurred in each group (one cardiac arrest in the control group and one episode of acute respiratory failure in the closed-loop group), both of which were unrelated to study interventions. There were no adverse events related to study interventions in either group. No episodes of severe hypoglycaemia or hyperglycaemia with ketonaemia occurred in either study group. INTERPRETATION: Closed-loop insulin delivery is an effective treatment option to improve glycaemic control in patients receiving nutritional support in hospital. FUNDING: Diabetes UK, Swiss National Science Foundation, National Institute for Health Research Cambridge Biomedical Research Centre, Wellcome Trust, and European Foundation for the Study of Diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive versus Conventional Glucose Control in Critically Ill Patients
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810625 · Cited by 5,119
Closed-loop insulin delivery for glycemic control in noncritical care
Bally, L., Thabit, H., Hartnell, S., Andereggen, E., Ruan, Y., Wilinska, M. E., Evans, M. L., Wertli, M. M., Coll, A. P., Stettler, C., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1805233 · Cited by 232
Self-citation
Cited by
Cappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477
Management of diabetes and hyperglycaemia in the hospital
Pasquel, F. J., Lansang, M. C., Dhatariya, K., & Umpierrez, G. E. (2021) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(20)30381-8 · Cited by 329
Continuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline
Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., et al. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820954163 · Cited by 170
Self-citationDaly, A. B., Boughton, C. K., Nwokolo, M., Hartnell, S., Wilinska, M. E., Cezar, A., Evans, M. L., & Hovorka, R. (2023) · Nature Medicine · doi:10.1038/s41591-022-02144-z · Cited by 120
Self-citationDavis, G. M., Peters, A. L., Bode, B. W., Carlson, A. L., Dumais, B., Vienneau, T. E., Huyett, L. M., & Ly, T. T. (2023) · Diabetes Care · doi:10.2337/dc22-1915 · Cited by 69
Metadata
- Authors
- Boughton, C. K., Bally, L., Martignoni, F., Hartnell, S., Herzig, D., Vogt, A., Wertli, M. M., Wilinska, M. E., Evans, M. L., Coll, A. P., Stettler, C., & Hovorka, R.
- Venue
- The Lancet Diabetes & Endocrinology
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 7
- Issue
- 5
- Pages
- 368-377
- ISSN
- 2213-8587 (ISSN-L)
- OpenAlex
- W2934288869
- Cited by
- 110
- References
- 2
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully closed-loop insulin delivery in inpatients receiving nutritional support: a two-centre, open-label, randomised controlled trial. https://app.cochat.ai/papers/10.1016/s2213-8587(19)30061-0
- The paper
- Boughton, C. K., Bally, L., Martignoni, F., Hartnell, S., Herzig, D., Vogt, A., Wertli, M. M., Wilinska, M. E., Evans, M. L., Coll, A. P., Stettler, C., & Hovorka, R. (2019). Fully closed-loop insulin delivery in inpatients receiving nutritional support: a two-centre, open-label, randomised controlled trial. The Lancet Diabetes & Endocrinology. https://doi.org/10.1016/s2213-8587(19)30061-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.