The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Menstrual cup use, leakage, acceptability, safety, and availability: a systematic review and meta-analysis
Open accessAbstract
Background Girls and women need effective, safe, and affordable menstrual products.Single-use products are regularly selected by agencies for resource-poor settings; the menstrual cup is a less known alternative.We reviewed international studies on menstrual cup leakage, acceptability, and safety and explored menstrual cup availability to inform programmes. MethodsIn this systematic review and meta-analysis, we searched PubMed, Cochrane Library, Web of Science, Popline, Cinahl, Global Health database, Emerald, Google Scholar, Science.gov, and WorldWideScience from database inception to May 14, 2019, for quantitative or qualitative studies published in English on experiences and leakage associated with menstrual cups, and adverse event reports.We also screened the Manufacturer and User Facility Device Experience database from the US Food and Drug Administration for events related to menstrual cups.To be eligible for inclusion, the material needed to have information on leakage, acceptability, or safety of menstrual cups.The main outcome of interest was menstrual blood leakage when using a menstrual cup.Safety outcomes of interest included serious adverse events; vaginal abrasions and effects on vaginal microflora; effects on the reproductive, digestive, or urinary tract; and safety in poor sanitary conditions.Findings were tabulated or combined by use of forest plots (random-effects meta-analysis).We also did preliminary estimates on costs and environmental savings potentially associated with cups.This systematic review is registered on PROSPERO, number CRD42016047845.Findings Of 436 records identified, 43 studies were eligible for analysis (3319 participants).Most studies reported on vaginal cups (27 [63%] vaginal cups, five [12%] cervical cups, and 11 [25%] mixed types of cups or unknown) and 15 were from low-income and middle-income countries.22 studies were included in qualitative or quantitative syntheses, of which only three were of moderate-to-high quality.Four studies made a direct comparison between menstrual cups and usual products for the main outcome of leakage and reported leakage was similar or lower for menstrual cups than for disposable pads or tampons (n=293).In all qualitative studies, the adoption of the menstrual cup required a familiarisation phase over several menstrual cycles and peer support improved uptake (two studies in developing countries).In 13 studies, 73% (pooled estimate: n=1144; 95% CI 59-84, I²=96%) of participants wished to continue use of the menstrual cup at study completion.Use of the menstrual cup showed no adverse effects on the vaginal flora (four studies, 507 women).We identified five women who reported severe pain or vaginal wounds, six reports of allergies or rashes, nine of urinary tract complaints (three with hydronephrosis), and five of toxic shock syndrome after use of the menstrual cup.Dislodgement of an intrauterine device was reported in 13 women who used the menstrual cup (eight in case reports, and five in one study) between 1 week and 13 months of insertion of the intrauterine device.Professional assistance to aid removal of menstrual cup was reported among 47 cervical cup users and two vaginal cup users.We identified 199 brands of menstrual cup, and availability in 99 countries with prices ranging US$0•72-46•72 (median $23•3, 145 brands).Interpretation Our review indicates that menstrual cups are a safe option for menstruation management and are being used internationally.Good quality studies in this field are needed.Further studies are needed on costeffectiveness and environmental effect comparing different menstrual products.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Dermyshi, E., Wang, Y., Yan, C., Hong, W., Qiu, G., Gong, X., & Zhang, T. (2017) · Neonatology · doi:10.1159/000454668 · Cited by 24,451
(2014) · Medical Entomology and Zoology · Cited by 17,633
Menstrual hygiene management among adolescent girls in India: a systematic review and meta-analysis
van Eijk, A. M., Sivakami, M., Thakkar, M. B., Bauman, A., Laserson, K. F., Coates, S., & Phillips-Howard, P. A. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010290 · Cited by 471
Self-citationDas, P., Baker, K. K., Dutta, A., Swain, T., Sahoo, S., Das, B. S., Panda, B., Nayak, A., Bara, M., Bilung, B., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0130777 · Cited by 441
A Time for Global Action: Addressing Girls’ Menstrual Hygiene Management Needs in Schools
Sommer, M., Caruso, B. A., Sahin, M., Calderon, T., Cavill, S., Mahon, T., & Phillips-Howard, P. A. (2016) · PLOS Medicine · doi:10.1371/journal.pmed.1001962 · Cited by 435
Self-citationMason, L., Nyothach, E., Alexander, K., Odhiambo, F. O., Eleveld, A., Vulule, J., Rheingans, R., Laserson, K. F., Mohammed, A., & Phillips-Howard, P. A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0079132 · Cited by 375
Self-citationSommer, M. (2010) · Journal of Adolescence · doi:10.1016/j.adolescence.2009.03.008 · Cited by 305
Torondel, B., Sinha, S., Mohanty, J. R., Swain, T., Sahoo, P., Panda, B., Nayak, A., Bara, M., Bilung, B., Cumming, O., et al. (2018) · BMC Infectious Diseases · doi:10.1186/s12879-018-3384-2 · Cited by 259
Managing menstruation in the workplace: An overlooked issue in low- and middle income countries
Sommer, M., Chandraratna, S., Cavill, S., Mahon, T., & Phillips-Howard, P. (2016) · International Journal for Equity in Health · doi:10.1186/s12939-016-0379-8 · Cited by 254
Cited by
Menstruation: science and society
Critchley, H. O. D., Babayev, E., Bulun, S. E., Clark, S., Garcia-Grau, I., Gregersen, P. K., Kilcoyne, A., Kim, J.-Y. J., Lavender, M., Marsh, E. E., et al. (2020) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.06.004 · Cited by 448
Metadata
- Authors
- van Eijk, A. M., Zulaika, G., Lenchner, M., Mason, L., Sivakami, M., Nyothach, E., Unger, H., Laserson, K., & Phillips-Howard, P. A.
- Venue
- The Lancet Public Health
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 4
- Issue
- 8
- Pages
- e376-e393
- ISSN
- 2468-2667 (ISSN-L)
- OpenAlex
- W2962114409
- Cited by
- 287
- References
- 53
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Menstrual cup use, leakage, acceptability, safety, and availability: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/s2468-2667(19)30111-2
- The paper
- van Eijk, A. M., Zulaika, G., Lenchner, M., Mason, L., Sivakami, M., Nyothach, E., Unger, H., Laserson, K., & Phillips-Howard, P. A. (2019). Menstrual cup use, leakage, acceptability, safety, and availability: a systematic review and meta-analysis. The Lancet Public Health. https://doi.org/10.1016/s2468-2667(19)30111-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.