FDA-cleared artificial intelligence and machine learning-based medical devices and their 510(k) predicate networks
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The US Food and Drug Administration is clearing an increasing number of artificial intelligence and machine learning (AI/ML)-based medical devices through the 510(k) pathway. This pathway allows clearance if the device is substantially equivalent to a former cleared device (ie, predicate). We analysed the predicate networks of cleared AI/ML-based medical devices (cleared between 2019 and 2021), their underlying tasks, and recalls. More than a third of cleared AI/ML-based medical devices originated from non-AI/ML-based medical devices in the first generation. Devices with the longest time since the last predicate device with an AI/ML component were haematology (2001), radiology (2001), and cardiovascular devices (2008). Especially for devices in radiology, the AI/ML tasks changed frequently along the device's predicate network, raising safety concerns. To date, only a few recalls might have affected the AI/ML components. To improve patient care, a stronger focus should be placed on the distinctive characteristics of AI/ML when defining substantial equivalence between a new AI/ML-based medical device and predicate devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artificial intelligence in healthcare
Yu, K.-H., Beam, A. L., & Kohane, I. S. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0305-z · Cited by 2,817
Zhu, S., Gilbert, M., Chetty, I., & Siddiqui, F. (2022) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2022.104828 · Cited by 131
Cited by
Ng, F. Y. C., Thirunavukarasu, A. J., Cheng, H., Tan, T. F., Gutierrez, L., Lan, Y., Ong, J. C. L., Chong, Y. S., Ngiam, K. Y., Ho, D., et al. (2023) · Cell Reports Medicine · doi:10.1016/j.xcrm.2023.101230 · Cited by 113
How AI is used in FDA-authorized medical devices: a taxonomy across 1,016 authorizations
Singh, R., Bapna, M., Diab, A. R., Ruiz, E. S., & Lotter, W. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01800-1 · Cited by 61
McNamara, S. L., Yi, P. H., & Lotter, W. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01080-1 · Cited by 60
AI in imaging: the regulatory landscape
Hill, D. L. G. (2024) · British Journal of Radiology · doi:10.1093/bjr/tqae002 · Cited by 52
Benefit-Risk Reporting for FDA-Cleared Artificial Intelligence−Enabled Medical Devices
Lin, J. C., Jain, B., Iyer, J. M., Rola, I., Srinivasan, A. R., Kang, C., Patel, H., & Parikh, R. B. (2025) · JAMA Health Forum · doi:10.1001/jamahealthforum.2025.3351 · Cited by 42
Metadata
- Authors
- Muehlematter, U. J., Bluethgen, C., & Vokinger, K. N.
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2023-09
- Volume
- 5
- Issue
- 9
- Pages
- e618-e626
- ISSN
- 2589-7500 (ISSN-L)
- OpenAlex
- W4386110494
- Cited by
- 113
- References
- 2
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FDA-cleared artificial intelligence and machine learning-based medical devices and their 510(k) predicate networks. https://app.cochat.ai/papers/10.1016/s2589-7500(23)00126-7
- The paper
- Muehlematter, U. J., Bluethgen, C., & Vokinger, K. N. (2023). FDA-cleared artificial intelligence and machine learning-based medical devices and their 510(k) predicate networks. The Lancet Digital Health. https://doi.org/10.1016/s2589-7500(23)00126-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.