CoChat

Safety and efficacy of neurostimulation with a miniaturised vagus nerve stimulation device in patients with multidrug-refractory rheumatoid arthritis: a two-stage multicentre, randomised pilot study

Genovese, Mark C, Gaylis, Norman B, Sikes, David, Kivitz, Alan, Lewis Horowitz, Diane, Peterfy, Charles, Glass, Emmett V, Levine, Yaakov A, Chernoff, David · 2020 · The Lancet Rheumatology
Cited by 115

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

Background The inflammatory reflex plays a role in regulating innate and adaptive immunity by modulating cellular and molecular inflammatory pathways. The vagus nerve is a major constituent of the inflammatory reflex and studies have shown that the reflex can be activated by electrical stimulation of the vagus nerve. In this first in-human pilot study, we assessed the safety and efficacy of a novel miniaturised vagus nerve stimulation (VNS) device for the treatment of multidrug-refractory rheumatoid arthritis. METHODS Participants with moderately to severely active rheumatoid arthritis and prior insufficient response to two or more biological disease-modifying anti-rheumatic drugs or Janus kinase inhibitors with at least two different modes of action were enrolled in a two-stage study done at five clinical research sites in the USA. Stage 1 was open label; participants were implanted with a miniaturised VNS device, which was activated for 1 min once a day. In stage 2, participants were randomly assigned (1:1:1) to receive active stimulation (1 min once a day or 1 min four times a day) or sham stimulation (device implanted but not activated), with the sites and participants masked to treatment assignment. The primary outcome was incidence of treatment-emergent adverse events. Clinical efficacy was assessed as a key secondary outcome. The study was registered with ClinicalTrials.gov, NCT03437473. FINDINGS 14 patients were enrolled between March 13 and Aug 8, 2018. Three patients received stimulation in stage 1 and, following safety review board approval, the remaining 11 patients were implanted during stage 2 and randomly assigned to receive 1 min of stimulation once daily (n=3), 1 min of stimulation four times daily (n=4), or no stimulation (n=4) for 12 weeks. There were no device-related or treatment-related serious adverse events. Surgery-related adverse events were Horner's syndrome and vocal cord paralysis (in one patient each), which resolved without clinically significant sequelae. No deaths were recorded. INTERPRETATION VNS with a miniaturised neurostimulator was safe and well tolerated and reduced signs and symptoms of rheumatoid arthritis in patients with multidrug-refractory disease. These results support further evaluation in a larger randomised sham-controlled study. FUNDING SetPoint Medical.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s2665-9913(20)30172-7

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Research works printed but not linked: 4

  1. Heck, 2002, Vagus nerve stimulation therapy, epilepsy, and device parameters: scientific basis and recommendations for use, Neurology, 59, S31
  2. D'Haens, 2016, Clinical trial of the effects of vagus nerve stimulation in biologic-refractory Crohn's disease, United European Gastroenterol J, 4, A641
  3. Peterfy, 2016, MRI assessment of suppression of structural damage in patients with rheumatoid arthritis receiving rituximab: results from the randomised, placebo-controlled, double-blind RA-SCORE study, Ann Rheum Dis, 75, 170, 10.1136/annrheumdis-2014-206015 · doi:10.1136/annrheumdis-2014-206015
  4. Rendas-Baum, 2011, Evaluating the efficacy of sequential biologic therapies for rheumatoid arthritis patients with an inadequate response to tumor necrosis factor-α inhibitors, Arthritis Res Ther, 13, R25, 10.1186/ar3249 · DOI

Cited by

Metadata

Authors
Genovese, M. C., Gaylis, N. B., Sikes, D., Kivitz, A., Lewis Horowitz, D., Peterfy, C., Glass, E. V., Levine, Y. A., & Chernoff, D.
Venue
The Lancet Rheumatology
Publisher
Elsevier BV
Published
2020-09
Volume
2
Issue
9
Pages
e527-e538
ISSN
2665-9913
Cited by
115
References
30
Language
en
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.