CoChat

488. An improved method of observing the clotting of milk containing rennin

Berridge, N. J. · 1952 · Journal of Dairy Research
Cited by 103

The DOI matches its Crossref record.

Abstract

The method of assaying rennin described by Berridge(1) requires the formation under reproducible conditions of a thin flowing film of milk. Although the skill needed to keep the film flowing at the optimum rate as the clotting point is approached is readily acquired, an automatic method has the advantage of complete reproducibility. A suitable film can be maintained if 10 ml. of milk are placed in a boiling tube of 2·2 cm. internal diameter and the tube, with its axis inclined at about 30° to the horizontal, rotated at 3·0 r.p.m. In the apparatus now used, the boiling tube is mounted on a rubber bung, which in turn is mounted concentrically on a spindle connected through Meccano gears to a 'Sangamo' electric clock motor. A special mechanical coupling allows the bung to be rotated by hand one revolution forwards, thus allowing 20 sec. for fitting or releasing the boiling tube before the drive is again taken up.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0022029900006567

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 103

Metadata

Authors
Berridge, N. J.
Venue
Journal of Dairy Research
Published
1952-10
Volume
19
Issue
3
Pages
328-329
ISSN
  • 0022-0299 (ISSN-L)
  • 1469-7629
OpenAlex
W2002820205
Cited by
103
References
0
FWCI
2.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 488. An improved method of observing the clotting of milk containing rennin. https://app.cochat.ai/papers/10.1017/s0022029900006567
The paper
Berridge, N. J. (1952). 488. An improved method of observing the clotting of milk containing rennin. Journal of Dairy Research. https://doi.org/10.1017/s0022029900006567

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.