Assessment of two instruments for continuous measurement of the curd-firming of renneted milk
The DOI matches its Crossref record.
Abstract
SUMMARY: Continuous measurements of curd-firming using a commercial vibratingreed viscometer and a pressure transmission system (PTS) developed at this Institute were compared both in the laboratory and during Cheddar cheesemaking. The coefficient of variation about the mean of the curd-firmness measured in reconstituted skim-milk 40 min after renneting was 3·5% with the viscometer and 2·6% with the PTS. The effects of changes in conditions on the curd-firming rate of raw whole milk were determined. As the rennet concentration was raised the rates increased linearly as measured by the viscometer, but non-linearly as measured by the PTS. Addition of CaCl 2 increased the rates measured by both instruments rapidly at first then more slowly at higher levels. Raising the temperature increased the rate exponentially in the case of the viscometer but more slowly with the PTS. With both instruments the curd-firming rates of milk at pH 5·8 were 6·5 times those at pH 6·7 but the rates fell slightly at pH 5·6. In experimental cheesemaking, the mean readings of both instruments at the subjectively determined cutting time of the curd had the same coefficient of variation. The commercial viscometer is probably more suitable for laboratory investigations of the earlier stages of the coagulation of milk by rennet whilst the PTS may prove the more useful in indicating the optimum cutting time of the curd during cheesemaking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Formation and physical properties of milk protein gels
Lucey, J. A. (2002) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(02)74078-2 · Cited by 667
Importance of Calcium and Phosphate in Cheese Manufacture: A Review
Lucey, J. A., & Fox, P. F. (1993) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(93)77504-9 · Cited by 454
(2007) · CRC Press eBooks · doi:10.1201/9781439823859 · Cited by 200
Glycolysis and related reactions during cheese manufacture and ripening
Fox, P. F., Lucey, J. A., & Cogan, T. M. (1990) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408399009527526 · Cited by 199
Secondary (Non-enzymatic) Phase of Rennet Coagulation and Post-coagulation Phenomena
Green, M. L., & Grandison, A. S. (1993) · Cheese: Chemistry, Physics and Microbiology · doi:10.1007/978-1-4615-2650-6_4 · Cited by 70
Self-citation
Metadata
- Authors
- Marshall, R. J., Hatfield, D. S., & Green, M. L.
- Venue
- Journal of Dairy Research
- Publisher
- Cambridge University Press (CUP)
- Published
- 1982-02
- Volume
- 49
- Issue
- 1
- Pages
- 127-135
- ISSN
- 0022-0299 (ISSN-L)
- 1469-7629
- OpenAlex
- W1994952301
- Cited by
- 43
- References
- 0
- FWCI
- 10.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of two instruments for continuous measurement of the curd-firming of renneted milk. https://app.cochat.ai/papers/10.1017/s0022029900022202
- The paper
- Marshall, R. J., Hatfield, D. S., & Green, M. L. (1982). Assessment of two instruments for continuous measurement of the curd-firming of renneted milk. Journal of Dairy Research. https://doi.org/10.1017/s0022029900022202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.