The efficiency of a turbine in a tidal channel
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
There is an upper bound to the amount of power that can be generated by turbines in tidal channels as too many turbines merely block the flow. One condition for achievement of the upper bound is that the turbines are deployed uniformly across the channel, with all the flow through them, but this may interfere with other uses of the channel. An isolated turbine is more effective in a channel than in an unbounded flow, but the current downstream is non-uniform between the wake of the turbines and the free stream. Hence some energy is lost when these streams merge, as may occur in a long channel. We show here, for ideal turbine models, that the fractional power loss increases from 1/3 to 2/3 as the fraction of the channel cross-section spanned by the turbines increases from 0 to close to 1. In another scenario, possibly appropriate for a short channel, the speed of the free stream outside the turbine wake is controlled by separation at the channel exit. In this case, the maximum power obtainable is slightly less than proportional to the fraction of the channel cross-section occupied by turbines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tidal current energy assessment for Johnstone Strait, Vancouver Island
Sutherland, G., Foreman, M. G. G., & Garrett, C. (2007) · Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy · doi:10.1243/09576509jpe338 · Cited by 187
Self-citationA CONTRIBUTION TO THE THEORY OF PROPULSION AND THE SCREW PROPELLER
Lanchester, F. W. (1915) · Journal of the American Society of Naval Engineers · doi:10.1111/j.1559-3584.1915.tb00408.x · Cited by 149
The Lanchester-Betz limit (energy conversion efficiency factor for windmills)
Bergey, K. H. (1979) · Journal of Energy · doi:10.2514/3.48013 · Cited by 89
Cited by
Current tidal power technologies and their suitability for applications in coastal and marine areas
Roberts, A., Thomas, B., Sewell, P., Khan, Z., Balmain, S., & Gillman, J. (2016) · Journal of Ocean Engineering and Marine Energy · doi:10.1007/s40722-016-0044-8 · Cited by 166
“As a result of this constriction, the power coefficient of an unducted axial turbine situated between two rigid surfaces (such as the walls of a tidal channel) is increased by a factor of E (Garrett and Cummins 2007):”
BackgroundThermodynamic Foundations of the Earth System
Kleidon, A. (2016) · doi:10.1017/cbo9781139342742 · Cited by 133
Integration of tidal energy into an island energy system – A case study of Orkney islands
Almoghayer, M. A., Woolf, D. K., Kerr, S., & Davies, G. (2022) · Energy · doi:10.1016/j.energy.2021.122547 · Cited by 56
Metadata
- Authors
- GARRETT, C., & CUMMINS, P.
- Venue
- Journal of Fluid Mechanics
- Publisher
- Cambridge University Press (CUP)
- Published
- 2007-09-24
- Volume
- 588
- Pages
- 243-251
- ISSN
- 0022-1120 (ISSN-L)
- 1469-7645
- OpenAlex
- W1979101911
- Cited by
- 363
- References
- 3
- FWCI
- 18.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The efficiency of a turbine in a tidal channel. https://app.cochat.ai/papers/10.1017/s0022112007007781
- The paper
- GARRETT, C., & CUMMINS, P. (2007). The efficiency of a turbine in a tidal channel. Journal of Fluid Mechanics. https://doi.org/10.1017/s0022112007007781
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.