A slit sampler for collecting and counting air-borne bacteria
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. A slit sampler for air-borne bacteria is described, in which air is sucked through a narrow slit on to the surface of agar in an ordinary Petri dish. 2. This method has proved very rapid and simple in use, and has appeared more efficient than other methods against which it has been tested. 3. The collection efficiency for an aerosol consisting of Staph. albus, sprayed from distilled water as single cocci, is about 96%. The method thus collects the finest bacteria-carrying, particles almost as efficiently as coarser ones. 4. In contrast to this, the exposure of plain open Petri dishes appears to collect the larger particles in the air of crowded rooms at least 200 times as efficiently as it does single washed bacteria. This highly selective effect renders it advisable to use great caution in evaluating tests made in plain open dishes. 5. The methods of determining sampling efficiency, and their errors are discussed in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
WELLS, W. F. (1936) · Journal of the American Medical Association · doi:10.1001/jama.1936.02770470016004 · Cited by 128
Cited by
Primary biological aerosol particles in the atmosphere: a review
Després, V. R., Huffman, J. A., Burrows, S. M., Hoose, C., Safatov, A. S., Buryak, G., Fröhlich-Nowoisky, J., Elbert, W., Andreae, M. O., Pöschl, U., et al. (2012) · Tellus B: Chemical and Physical Meteorology · doi:10.3402/tellusb.v64i0.15598 · Cited by 1,500
“The most common single-stage impactor used for microbiological sampling has been the relatively simple slit-to-agar sampler (Henningson and Ahlberg, 1994), first developed by Bourdillon et al. (1941) and capable of providing CFU counts with high time resolution of approximately 1 h.”
MethodThe Microbiology of the Atmosphere
Kramer, C. L., & Gregory, P. H. (1974) · Mycologia · doi:10.2307/3758380 · Cited by 976
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850
Testing the Efficacy of Homemade Masks: Would They Protect in an Influenza Pandemic?
Davies, A., Thompson, K.-A., Giri, K., Kafatos, G., Walker, J., & Bennett, A. (2013) · Disaster Medicine and Public Health Preparedness · doi:10.1017/dmp.2013.43 · Cited by 498
Ghosh, B., Lal, H., & Srivastava, A. (2015) · Environment International · doi:10.1016/j.envint.2015.09.018 · Cited by 376
The microbiology of the atmosphere
Gregory, P. H. (1961) · L. Hill eBooks · doi:10.5962/bhl.title.7291 · Cited by 332
Bioaerosol sampling: sampling mechanisms, bioefficiency and field studies
Haig, C. W., Mackay, W. G., Walker, J. T., & Williams, C. (2016) · Journal of Hospital Infection · doi:10.1016/j.jhin.2016.03.017 · Cited by 228
“117 The sampling period will be influenced by factors that include the operational limitations of the sampling devices, such as the rate of evaporation of the collecting liquid, or the amount of time one has access to a site.”
BackgroundThe assessment of bioaerosols: A critical review
Griffiths, W. D., & DeCosemo, G. A. L. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90218-6 · Cited by 215
Cabral, J. P. S. (2010) · Science of The Total Environment · doi:10.1016/j.scitotenv.2010.07.005 · Cited by 194
Metadata
- Authors
- Bourdillon, R. B., Lidwell, O. M., & Thomas, J. C.
- Venue
- Journal of Hygiene
- Publisher
- Cambridge University Press (CUP)
- Published
- 1941-09
- Volume
- 41
- Issue
- 2
- Pages
- 197-224
- ISSN
- 0022-1724 (ISSN-L)
- OpenAlex
- W1995883118
- Cited by
- 188
- References
- 1
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.