The Influence of the Humidity of the Air on Capacity for Work at High Temperatures
Open accessThe DOI matches its Crossref record.
Abstract
The physiological reactions of two subjects were investigated in air at a temperature of 70–100° F., and of 40–96 per cent. relative humidity. The experiments lasted 3 hours, and one of the subjects performed mechanical work (step climbing) at the rate of 14,000 kg. m. per hour. The pulse rate was about 10 beats greater in dry air than in moist air of the same wet-bulb temperature. The winter observations agreed well with the effective temperature scale, but did not agree with the wet bulb, the dry-bulb or the kata-thermometer scales. Acclimatisation effects showed themselves in experiments made at a dry-bulb temperature of 87° F. or more, but only very slightly in those made at 81° or less. Acclimatisation was fairly well marked in the summer, the pulse rate being 5 to 10 beats less than in the winter, and no longer agreeing with the effective temperature scale. The body temperature corresponded with the pulse rate, for it was 0·3–0·6° F. higher in dry air than in moist air of the same wet-bulb temperature, and was 0·15° lower in summer than in winter. The winter observations agreed well with the effective temperature scale. The skin temperature of the face was found to depend on the dry-bulb temperature of the air, but that of the trunk showed no agreement with any of the scales. In moist air it was 1° F. lower than that of the face, and in dry air, 6° lower, owing to the cooling effect of increased sweating. The gross mechanical efficiency fell off slightly at temperatures above 70 or 75° F. It was affected by the dry-bulb temperature of the air as well as the wet bulb, but not to the extent indicated by the effective temperature scale. The weight of moisture lost by sweating corresponded well with the effective temperature scale. It increased gradually in consecutive experiments made in dry air, and diminished in those made in moist air. The degree of fatigue experienced in dry air was considerably greater than in moist air of the same wet-bulb temperature, and it corresponded with the effective temperature scale. Acknowledgments. We wish, to express our indebtedness to the authorities at the London School of Hygiene and Tropical Medicine, and especially to Dr G. P. Crowden, for the facilities offered to us in our work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Comparison of UTCI to selected thermal indices
Blazejczyk, K., Epstein, Y., Jendritzky, G., Staiger, H., & Tinz, B. (2012) · International Journal of Biometeorology · doi:10.1007/s00484-011-0453-2 · Cited by 1,129
Thermal Comfort and the Heat Stress Indices
EPSTEIN, Y., & MORAN, D. S. (2006) · Industrial Health · doi:10.2486/indhealth.44.388 · Cited by 920
A review into thermal comfort in buildings
Taleghani, M., Tenpierik, M., Kurvers, S., & van den Dobbelsteen, A. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.05.050 · Cited by 357
A comprehensive catalogue and classification of human thermal climate indices
de Freitas, C. R., & Grigorieva, E. A. (2015) · International Journal of Biometeorology · doi:10.1007/s00484-014-0819-3 · Cited by 297
A comparison and appraisal of a comprehensive range of human thermal climate indices
de Freitas, C. R., & Grigorieva, E. A. (2017) · International Journal of Biometeorology · doi:10.1007/s00484-016-1228-6 · Cited by 275
Metadata
- Authors
- Vernon, H. M., & Warner, C. G.
- Venue
- Journal of Hygiene
- Publisher
- Cambridge University Press (CUP)
- Published
- 1932-07
- Volume
- 32
- Issue
- 3
- Pages
- 431-462
- ISSN
- 0022-1724 (ISSN-L)
- OpenAlex
- W2144080704
- Cited by
- 106
- References
- 0
- FWCI
- 8.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Influence of the Humidity of the Air on Capacity for Work at High Temperatures. https://app.cochat.ai/papers/10.1017/s0022172400018167
- The paper
- Vernon, H. M., & Warner, C. G. (1932). The Influence of the Humidity of the Air on Capacity for Work at High Temperatures. Journal of Hygiene. https://doi.org/10.1017/s0022172400018167
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.