Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 209

The DOI matches its Crossref record.

A Gas Ion Source for Radiocarbon Measurements at 200 kV

Open access
Ruff, M, Wacker, L, Gäggeler, H W, Suter, M, Synal, H-A, Szidat, S · 2007 · Radiocarbon

Abstract

The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO 2 samples. The source produces stable currents of up to 6 μA C− out of gaseous samples with an efficiency of 3–6%. A gas feeding system has been set up that enables constant dosing of CO 2 into the Cs sputter ion source and ensures stable measuring conditions. The system is based on a syringe in which CO 2 gas is mixed with He and then pressed continuously into the ion source at a constant flow rate. Minimized volumes allow feeding samples of 3–30 μg carbon quantitatively into the ion source. In order to test the performance of the system, several standards and blanks have successfully been measured. The ratios of 14 C/12 C could be repeated within statistical errors to better than 1.0% and the 13 C/12 C ratios to better than 0.2%. The blank was <1 pMC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0033822200042235

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 209

Metadata

Authors
Ruff, M., Wacker, L., Gäggeler, H. W., Suter, M., Synal, H.-A., & Szidat, S.
Venue
Radiocarbon
Published
2007
Volume
49
Issue
2
Pages
307-314
ISSN
  • 0033-8222 (ISSN-L)
  • 1945-5755
OpenAlex
W1927754270
Cited by
209
References
0
FWCI
7.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Gas Ion Source for Radiocarbon Measurements at 200 kV. https://app.cochat.ai/papers/10.1017/s0033822200042235
The paper
Ruff, M., Wacker, L., Gäggeler, H. W., Suter, M., Synal, H.-A., & Szidat, S. (2007). A Gas Ion Source for Radiocarbon Measurements at 200 kV. Radiocarbon. https://doi.org/10.1017/s0033822200042235

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.