Design and kinematic characterization of a surgical manipulator with a focus on treating osteolysis
The DOI matches its Crossref record.
Abstract
SUMMARY: This paper presents a cable-driven dexterous manipulator with a large, open lumen. One specific application for the manipulator is the treatment of the degeneration of bone tissue (osteolysis) during a less-invasive hip revision surgery. Rigid tools used in traditional approaches limit the surgeons' ability to comprehensively treat the osteolysis due to the complex geometries of the lesion. The surgical scenario, testing, kinematic modeling, and image-based inverse kinematics are described. Testing shows 94% coverage of a lesion wall; the kinematic model describes manipulator notch positions within 0.15 mm, while the image-based inverse kinematics has 0.36 mm error. This manipulator is potentially useful in treating osteolytic lesions through (1) effective lesion exploration compared to conventional techniques, and (2) rapidly performing inverse kinematics from visual feedback.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Russo, M., Sadati, S. M. H., Dong, X., Mohammad, A., Walker, I. D., Bergeles, C., Xu, K., & Axinte, D. A. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200367 · Cited by 263
Simaan, N., Yasin, R. M., & Wang, L. (2018) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-104956 · Cited by 182
“Kinematics of a flexure-based single backbone continuum robot was characterized using image analysis and constrained optimization in [45].”
MethodReview of snake robots in constrained environments
Liu, J., Tong, Y., & Liu, J. (2021) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2021.103785 · Cited by 178
Enabling machine learning in X-ray-based procedures via realistic simulation of image formation
Unberath, M., Zaech, J.-N., Gao, C., Bier, B., Goldmann, F., Lee, S. C., Fotouhi, J., Taylor, R., Armand, M., & Navab, N. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-02011-2 · Cited by 63
Self-citationAlambeigi, F., Aghajani Pedram, S., Speyer, J. L., Rosen, J., Iordachita, I., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2946726 · Cited by 48
“The CM used for performing the experiments is a cable-driven CM, called “ortho-snake,” which has been specifically designed for orthopedic applications [36].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Murphy, R. J., Kutzer, M. D. M., Segreti, S. M., Lucas, B. C., & Armand, M.
- Venue
- Robotica
- Publisher
- Cambridge University Press (CUP)
- Published
- 2013-12-03
- Volume
- 32
- Issue
- 6
- Pages
- 835-850
- ISSN
- 0263-5747 (ISSN-L)
- 1469-8668
- OpenAlex
- W2125817642
- Cited by
- 73
- References
- 0
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and kinematic characterization of a surgical manipulator with a focus on treating osteolysis. https://app.cochat.ai/papers/10.1017/s0263574713001082
- The paper
- Murphy, R. J., Kutzer, M. D. M., Segreti, S. M., Lucas, B. C., & Armand, M. (2014). Design and kinematic characterization of a surgical manipulator with a focus on treating osteolysis. Robotica. https://doi.org/10.1017/s0263574713001082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.