Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 162

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis

Marx, G., Cope, T., McCrossan, L., Swaraj, S., Cowan, C., Mostafa, S. M., Wenstone, R., Leuwer, M. · 2004 · European Journal of Anaesthesiology

Abstract

BACKGROUND AND OBJECTIVE: Our hypothesis was that stroke volume variation during mechanical ventilation of the lungs would allow accurate prediction and monitoring of changes in cardiac index in response to fluid loading in patients with severe sepsis. METHODS: This was a prospective clinical study in a university hospital. Ten mechanically ventilated patients with severe sepsis or septic shock were given fluid loading with 500 mL 10% hydroxyethylstarch 200/0.5 over 30 min. Before and after fluid loading pulmonary arterial occlusion pressure and central venous pressure were measured. Intrathoracic blood volume index, stroke volume variation and cardiac index were measured by the transpulmonary thermodilution technique. After verifying normal distribution of the data (skewness < 1.0) the paired t-test was used for statistical analysis. RESULTS: After fluid loading stroke volume variation decreased significantly, whereas central venous pressure, pulmonary arterial occlusion pressure, intrathoracic blood volume index and cardiac index increased significantly. Changes of cardiac index in response to fluid loading were correlated to baseline values of stroke volume variation (r = 0.64, P = 0.02) and intrathoracic blood volume index (r = -0.73, P = 0.009). Changes in cardiac index were significantly correlated to percentage changes in stroke volume variation (r = -0.65, P < 0.001) and changes in intrathoracic blood volume index (r = 0.52, P = 0.002), whereas changes in cardiac index revealed no significant correlation to changes in central venous pressure (r = 0.28, P = 0.07) and changes in pulmonary arterial occlusion pressure (r = 0.29, P = 0.06). CONCLUSIONS: Measuring stroke volume variation may be a useful way of guiding fluid therapy in ventilated patients with severe sepsis because it allows estimation of preload and prediction of cardiac index changes in response to fluid loading.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0265021504002091

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Metadata

Authors
Marx, G., Cope, T., McCrossan, L., Swaraj, S., Cowan, C., Mostafa, S. M., Wenstone, R., & Leuwer, M.
Venue
European Journal of Anaesthesiology
Published
2004-02
Volume
21
Issue
2
Pages
132-138
ISSN
  • 0265-0215 (ISSN-L)
  • 1365-2346
OpenAlex
W2047144313
Cited by
162
References
2
FWCI
12.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis. https://app.cochat.ai/papers/10.1017/s0265021504002091
The paper
Marx, G., Cope, T., McCrossan, L., Swaraj, S., Cowan, C., Mostafa, S. M., Wenstone, R., & Leuwer, M. (2004). Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis. European Journal of Anaesthesiology. https://doi.org/10.1017/s0265021504002091

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.