JCPDS—International Centre for Diffraction Data round robin study of silver behenate. A possible low-angle X-ray diffraction calibration standard
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A task group of the JCPDS—International Center for Diffraction Data (ICDD) was established with the charge of investigating the use of silver behenate, CH 3 (CH 2 ) 20 COO·Ag, as a possible low-angle calibration standard for powder diffraction applications. Utilizing several data collection and analysis techniques, long-period spacing ( d 001 ) values with a range of 58.219–58.480 Å were obtained. Using the same collected data and one data analysis refinement calculation method resulted in dm values with a range of 58.303–58.425 Å. Data collected using a silicon internal standard and the same singular data analysis calculation method provided d 001 values with a range of 58.363–58.381 Å.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
X-ray powder diffraction analysis of silver behenate, a possible low-angle diffraction standard
Huang, T. C., Toraya, H., Blanton, T. N., & Wu, Y. (1993) · Journal of Applied Crystallography · doi:10.1107/s0021889892009762 · Cited by 634
Self-citation
Cited by
Crystallizing membrane proteins using lipidic mesophases
Caffrey, M., & Cherezov, V. (2009) · Nature Protocols · doi:10.1038/nprot.2009.31 · Cited by 670
The phase diagram of the monoolein/water system: metastability and equilibrium aspects
Qiu, H., & Caffrey, M. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00126-x · Cited by 640
Structure of Gel Phase DMPC Determined by X-Ray Diffraction
Tristram-Nagle, S., Liu, Y., Legleiter, J., & Nagle, J. F. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75333-2 · Cited by 356
Small-angle X-ray and neutron scattering
Jeffries, C. M., Ilavsky, J., Martel, A., Hinrichs, S., Meyer, A., Pedersen, J. S., Sokolova, A. V., & Svergun, D. I. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00064-9 · Cited by 256
Transfection Mediated by Gemini Surfactants: Engineered Escape from the Endosomal Compartment
Bell, P. C., Bergsma, M., Dolbnya, I. P., Bras, W., Stuart, M. C. A., Rowan, A. E., Feiters, M. C., & Engberts, J. B. F. N. (2003) · Journal of the American Chemical Society · doi:10.1021/ja020707g · Cited by 217
Ilavsky, J., Zhang, F., Andrews, R. N., Kuzmenko, I., Jemian, P. R., Levine, L. E., & Allen, A. J. (2018) · Journal of Applied Crystallography · doi:10.1107/s160057671800643x · Cited by 184
Molecular organization of cholesterol in polyunsaturated membranes: microdomain formation
Brzustowicz, M. R., Cherezov, V., Caffrey, M., Stillwell, W., & Wassall, S. R. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75394-0 · Cited by 161
“Sampleto-detector distance, typically 250 mm, was measured using a silver behenate standard (Blanton et al., 1995).”
Method
Metadata
- Authors
- Blanton, T. N., Huang, T. C., Toraya, H., Hubbard, C. R., Robie, S. B., Louër, D., Göbel, H. E., Will, G., Gilles, R., & Raftery, T.
- Venue
- Powder Diffraction
- Publisher
- Cambridge University Press (CUP)
- Published
- 1995-06
- Volume
- 10
- Issue
- 2
- Pages
- 91-95
- ISSN
- 0885-7156 (ISSN-L)
- 1945-7413
- OpenAlex
- W2025209357
- Cited by
- 210
- References
- 1
- FWCI
- 2.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.