The DOI matches its Crossref record.
The Use of Reference Intensity Ratios in X-Ray Quantitative Analysis
Abstract
Each of the RIR based methods for carrying out quantitative X-ray powder diffraction analysis are described and a consistent set of notation is developed. The so called “standardless” analysis procedures are shown to be a special case of the internal-standard method of analysis where the normalizing assumption is used. All analytical methods, other than the Rietveld whole pattern matching procedure, require the use of explicitly measured standards, typically in the form of RIR values. However, if only semi-quantitative results can be tolerated, the standards may be obtained by using published RIR and relative intensity values. The exciting new techniques of whole pattern fitting and Rietveld constrained quantitative analysis are also described in RIR notation and shown also to be forms of the internal-standard method with the normalization assumption. The quantitative results obtained from Rietveld quantitative analysis are derived from computed standards in the form of computed, normalized, RIR N values. The normalization assumption in Rietveld analysis allows the exclusive use of computed standards and comes as close to a “standardless” analysis as one can achieve: relying on the absence of amorphous material and on the validity of the structural models. Relationships are given for obtaining quantitative analysis from these RIR N values obtainable from the least-squares scale factors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Impact of hydrated magnesium carbonate additives on the carbonation of reactive MgO cements
Unluer, C., & Al-Tabbaa, A. (2013) · Cement and Concrete Research · doi:10.1016/j.cemconres.2013.08.009 · Cited by 347
Enhancing the carbonation of MgO cement porous blocks through improved curing conditions
Unluer, C., & Al-Tabbaa, A. (2014) · Cement and Concrete Research · doi:10.1016/j.cemconres.2014.02.005 · Cited by 306
McCormack, J., Nehrke, G., Jöns, N., Immenhauser, A., & Kwiecien, O. (2019) · Chemical Geology · doi:10.1016/j.chemgeo.2019.03.014 · Cited by 49
Dung, N. T., & Unluer, C. (2020) · Advances in Cement Research · doi:10.1680/jadcr.17.00186 · Cited by 37
Metadata
- Authors
- Snyder, R. L.
- Venue
- Powder Diffraction
- Publisher
- Cambridge University Press (CUP)
- Published
- 1992-12
- Volume
- 7
- Issue
- 4
- Pages
- 186-193
- ISSN
- 0885-7156 (ISSN-L)
- 1945-7413
- OpenAlex
- W2047577173
- Cited by
- 200
- References
- 0
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use of Reference Intensity Ratios in X-Ray Quantitative Analysis. https://app.cochat.ai/papers/10.1017/s0885715600018686
- The paper
- Snyder, R. L. (1992). The Use of Reference Intensity Ratios in X-Ray Quantitative Analysis. Powder Diffraction. https://doi.org/10.1017/s0885715600018686
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.