The Effects of Closed-Loop Medical Devices on the Autonomy and Accountability of Persons and Systems
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Closed-loop medical devices such as brain-computer interfaces are an emerging and rapidly advancing neurotechnology. The target patients for brain-computer interfaces (BCIs) are often severely paralyzed, and thus particularly vulnerable in terms of personal autonomy, decisionmaking capacity, and agency. Here we analyze the effects of closed-loop medical devices on the autonomy and accountability of both persons (as patients or research participants) and neurotechnological closed-loop medical systems. We show that although BCIs can strengthen patient autonomy by preserving or restoring communicative abilities and/or motor control, closed-loop devices may also create challenges for moral and legal accountability. We advocate the development of a comprehensive ethical and legal framework to address the challenges of emerging closed-loop neurotechnologies like BCIs and stress the centrality of informed consent and refusal as a means to foster accountability. We propose the creation of an international neuroethics task force with members from medical neuroscience, neuroengineering, computer science, medical law, and medical ethics, as well as representatives of patient advocacy groups and the public.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Biomedical Ethics
(2012) · Thieves of Virtue · doi:10.7551/mitpress/9079.003.0009 · Cited by 13,453
Cited by
Technology of deep brain stimulation: current status and future directions
Krauss, J. K., Lipsman, N., Aziz, T., Boutet, A., Brown, P., Chang, J. W., Davidson, B., Grill, W. M., Hariz, M. I., Horn, A., et al. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00426-z · Cited by 919
Clinical AI: opacity, accountability, responsibility and liability
Smith, H. (2021) · AI & SOCIETY · doi:10.1007/s00146-020-01019-6 · Cited by 245
Embodiment and estrangement: results from a first-in-human “intelligent BCI” trial
Gilbert, F., Cook, M., O’Brien, T., & Illes, J. (2019) · Science and Engineering Ethics · doi:10.1007/s11948-017-0001-5 · Cited by 129
“It is unclear, however, how DBS studies translate to closed-loop BCI research (Kellmeyer et al. 2016).”
BackgroundDoing things with thoughts: brain–computer interfaces and disembodied agency
Steinert, S., Bublitz, C., Jox, R., & Friedrich, O. (2019) · Philosophy & Technology · doi:10.1007/s13347-018-0308-4 · Cited by 117
Artificial intelligence in basic and clinical neuroscience: Opportunities and ethical challenges.
Kellmeyer, P. (2019) · Neuroforum · doi:10.1515/nf-2019-0018 · Cited by 45
Self-citation
Metadata
- Authors
- KELLMEYER, P., COCHRANE, T., MÜLLER, O., MITCHELL, C., BALL, T., FINS, J. J., & BILLER-ANDORNO, N.
- Venue
- Cambridge Quarterly of Healthcare Ethics
- Publisher
- Cambridge University Press (CUP)
- Published
- 2016-09-16
- Volume
- 25
- Issue
- 4
- Pages
- 623-633
- ISSN
- 0963-1801 (ISSN-L)
- 1469-2147
- OpenAlex
- W2520856740
- Cited by
- 87
- References
- 1
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effects of Closed-Loop Medical Devices on the Autonomy and Accountability of Persons and Systems. https://app.cochat.ai/papers/10.1017/s0963180116000359
- The paper
- KELLMEYER, P., COCHRANE, T., MÜLLER, O., MITCHELL, C., BALL, T., FINS, J. J., & BILLER-ANDORNO, N. (2016). The Effects of Closed-Loop Medical Devices on the Autonomy and Accountability of Persons and Systems. Cambridge Quarterly of Healthcare Ethics. https://doi.org/10.1017/s0963180116000359
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.