The DOI matches its Crossref record.
Identifying and Correcting Scan Noise and Drift in the Scanning Transmission Electron Microscope
Abstract
The aberration-corrected scanning transmission electron microscope has great sensitivity to environmental or instrumental disturbances such as acoustic, mechanical, or electromagnetic interference. This interference can introduce distortions to the images recorded and degrade both signal noise and resolution performance. In addition, sample or stage drift can cause the images to appear warped and leads to unreliable lattice parameters being exhibited. Here a detailed study of the sources, natures, and effects of imaging distortions is presented, and from this analysis a piece of image reconstruction code has been developed that can restore the majority of the effects of these detrimental image distortions for atomic-resolution data. Example data are presented, and the performance of the restored images is compared quantitatively against the as-recorded data. An improvement in apparent resolution of 16% and an improvement in signal-to-noise ratio of 30% were achieved, as well as correction of the drift up to the precision to which it can be measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Machine learning for high performance organic solar cells: current scenario and future prospects
Mahmood, A., & Wang, J.-L. (2021) · Energy & Environmental Science · doi:10.1039/d0ee02838j · Cited by 378
Multifunctional High Entropy Alloys Enabled by Severe Lattice Distortion
Wang, H., He, Q., Gao, X., Shang, Y., Zhu, W., Zhao, W., Chen, Z., Gong, H., & Yang, Y. (2024) · Advanced Materials · doi:10.1002/adma.202305453 · Cited by 326
Nord, M., Vullum, P. E., MacLaren, I., Tybell, T., & Holmestad, R. (2017) · Advanced Structural and Chemical Imaging · doi:10.1186/s40679-017-0042-5 · Cited by 301
Restructuring of titanium oxide overlayers over nickel nanoparticles during catalysis
Monai, M., Jenkinson, K., Melcherts, A. E. M., Louwen, J. N., Irmak, E. A., Van Aert, S., Altantzis, T., Vogt, C., van der Stam, W., Duchoň, T., et al. (2023) · Science · doi:10.1126/science.adf6984 · Cited by 287
Metadata
- Authors
- Jones, L., & Nellist, P. D.
- Venue
- Microscopy and Microanalysis
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-05-14
- Volume
- 19
- Issue
- 4
- Pages
- 1050-1060
- ISSN
- 1431-9276 (ISSN-L)
- 1435-8115
- OpenAlex
- W2112983792
- Cited by
- 182
- References
- 0
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identifying and Correcting Scan Noise and Drift in the Scanning Transmission Electron Microscope. https://app.cochat.ai/papers/10.1017/s1431927613001402
- The paper
- Jones, L., & Nellist, P. D. (2013). Identifying and Correcting Scan Noise and Drift in the Scanning Transmission Electron Microscope. Microscopy and Microanalysis. https://doi.org/10.1017/s1431927613001402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.