Identifying and Correcting Scan Noise and Drift in the Scanning Transmission Electron Microscope
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The aberration-corrected scanning transmission electron microscope has great sensitivity to environmental or instrumental disturbances such as acoustic, mechanical, or electromagnetic interference. This interference can introduce distortions to the images recorded and degrade both signal noise and resolution performance. In addition, sample or stage drift can cause the images to appear warped and leads to unreliable lattice parameters being exhibited. Here a detailed study of the sources, natures, and effects of imaging distortions is presented, and from this analysis a piece of image reconstruction code has been developed that can restore the majority of the effects of these detrimental image distortions for atomic-resolution data. Example data are presented, and the performance of the restored images is compared quantitatively against the as-recorded data. An improvement in apparent resolution of 16% and an improvement in signal-to-noise ratio of 30% were achieved, as well as correction of the drift up to the precision to which it can be measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Sensitivity Performance of the Human Eye on an Absolute Scale*
Rose, A. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000196 · Cited by 931 · cited 1×
“~Rose, 1948!.”
Krivanek, O. L., Dellby, N., & Lupini, A. R. (1999) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00013-3 · Cited by 719 · cited 1×
“Much effort has been invested in improving the resolution of conventional transmission electron microscopes ~CTEM!, and scanning transmission electron microscopes ~STEM!, through the development of hardware aberration correctors ~Krivanek, 1999; Urban et al., 1999!.”
BackgroundPennycook, S. J., Chisholm, M. F., Lupini, A. R., Varela, M., Borisevich, A. Y., Oxley, M. P., Luo, W., van Benthem, K., Oh, S. H., Sales, D. L., et al. (2009) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2009.0112 · Cited by 114 · cited 1×
“The successful outcome of this work has made these microscopes among some of the most high-resolution and precise scientific instruments available, and with this development a range of imaging and spectroscopy techniques have all benefited, for example ~Pennycook et al., 2009!.”
BackgroundThe Structure of Grain Boundaries in Strontium Titanate: Theory, Simulation, and Electron Microscopy
von Alfthan, S., Benedek, N. A., Chen, L., Chua, A. L.-S., Cockayne, D. J. H., Dudeck, K. J., Elsässer, C., Finnis, M. W., Koch, C. T., Rahmati, B., et al. (2010) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-010510-104604 · Cited by 58 · cited 1×
“The author would like to acknowledge Professor Peng Wang for the data shown in Figure 3 and for his help with training in the MatLab language, and Dr. Karleen Dudeck for the data shown in Figure 11 ~von Alfthan et al., 2010!.”
MethodDevelopment of a stage-scanning system for high-resolution confocal STEM
Takeguchi, M., Hashimoto, A., Shimojo, M., Mitsuishi, K., & Furuya, K. (2008) · Journal of Electron Microscopy · doi:10.1093/jmicro/dfn010 · Cited by 57 · cited 1×
“Small drift rates of the order of 0.5–1.0 nm/min, or tens of picometers per second, are generally acceptable but can become significant when performing many-second “stationary” probe spectroscopy measurements ~Voyles & Muller, 2002; Klie et al., 2008; Takeguchi et al., 2008!.”
BackgroundInfluentialCorrecting scanning instabilities from images of periodic structures
Braidy, N., Bouar, Y. L., Lazar, S., & Ricolleau, C. (2012) · Ultramicroscopy · doi:10.1016/j.ultramic.2012.04.001 · Cited by 45
Cited by
Machine learning for high performance organic solar cells: current scenario and future prospects
Mahmood, A., & Wang, J.-L. (2021) · Energy & Environmental Science · doi:10.1039/d0ee02838j · Cited by 378
Multifunctional High Entropy Alloys Enabled by Severe Lattice Distortion
Wang, H., He, Q., Gao, X., Shang, Y., Zhu, W., Zhao, W., Chen, Z., Gong, H., & Yang, Y. (2024) · Advanced Materials · doi:10.1002/adma.202305453 · Cited by 326
Nord, M., Vullum, P. E., MacLaren, I., Tybell, T., & Holmestad, R. (2017) · Advanced Structural and Chemical Imaging · doi:10.1186/s40679-017-0042-5 · Cited by 301
Restructuring of titanium oxide overlayers over nickel nanoparticles during catalysis
Monai, M., Jenkinson, K., Melcherts, A. E. M., Louwen, J. N., Irmak, E. A., Van Aert, S., Altantzis, T., Vogt, C., van der Stam, W., Duchoň, T., et al. (2023) · Science · doi:10.1126/science.adf6984 · Cited by 287
Deep learning analysis on microscopic imaging in materials science
Ge, M., Su, F., Zhao, Z., & Su, D. (2020) · Materials Today Nano · doi:10.1016/j.mtnano.2020.100087 · Cited by 195
Metadata
- Authors
- Jones, L., & Nellist, P. D.
- Venue
- Microscopy and Microanalysis
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-05-14
- Volume
- 19
- Issue
- 4
- Pages
- 1050-1060
- ISSN
- 1431-9276 (ISSN-L)
- 1435-8115
- OpenAlex
- W2112983792
- Cited by
- 182
- References
- 6
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.