The DOI matches its Crossref record.
Multiresidue method for pesticides in drinking water using a graphitized carbon black cartridge extraction and liquid chromatographic analysis
Abstract
A general liquid-solid extraction procedure for the isolation of pesticides from groundwater and drinking water for high-performance liquid chromatography (HPLC) is presented. This simple and rapid procedure involved passing a 2-L sample through a 250-mg graphitized carbon black (Carbopack B) cartridge at a flow rate of 150-160 mL/min. By taking advantage of the presence of positively charged active centers on the Carbopack B surface, a stepwise elution system allowed the complete separation of base-neutral pesticides from acidic ones. After partial solvent removal, the components in the two fractions were separated and quantified by gradient elution, reversed-phase HPLC with ultraviolet (UV) detection. The performance of the Carbopack cartridge was compared with that of a 500-mg C-18 bonded silica cartridge. With the Carbopack cartridge, the grand mean measurement accuracy of the 35 pesticides considered was 95%. With the C-18 cartridge, the grand mean measurement accuracy of the analytes was 76%. Compared to the C-18 cartridge, additional advantages of using a Carbopack cartridge are that the extraction procedure is about 7 times shorter, no pH adjustment of the environmental sample is necessary for trapping acidic compounds, and one cartridge instead of two suffices to extract base-neutral and acidic pesticides, making the Carbopack cartridge more adaptable than the C-18 one for field use. The detection limits by this method of all the pesticides considered were between 0.003 and 0.07 micrograms/L.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography
Hennion, M.-C. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00832-8 · Cited by 1,044
Cai, Y., Jiang, G., Liu, J., & Zhou, Q. (2003) · Analytical Chemistry · doi:10.1021/ac0263566 · Cited by 503
Solid-phase extraction of phenols
Rodrı́guez, I., Llompart, M. P., & Cela, R. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00116-3 · Cited by 319
Metadata
- Authors
- Di Corcia, A., & Marchetti, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1991-03-15
- Volume
- 63
- Issue
- 6
- Pages
- 580-585
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1988879323
- Cited by
- 229
- References
- 0
- FWCI
- 34.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiresidue method for pesticides in drinking water using a graphitized carbon black cartridge extraction and liquid chromatographic analysis. https://app.cochat.ai/papers/10.1021/ac00006a007
- The paper
- Di Corcia, A., & Marchetti, M. (1991). Multiresidue method for pesticides in drinking water using a graphitized carbon black cartridge extraction and liquid chromatographic analysis. Analytical Chemistry. https://doi.org/10.1021/ac00006a007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.