The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Atmospheric Pressure Photoionization: An Ionization Method for Liquid Chromatography−Mass Spectrometry
Abstract
Atmospheric pressure photoionization (APPI) has been successfully demonstrated to provide high sensitivity to LC-MS analysis. A vacuum-ultraviolet lamp designed for photoionization detection in gas chromatography is used as a source of 10-eV photons. The mixture of samples and solvent eluting from an HPLC is fully evaporated prior to introduction into the photoionization region. In the new method, large quantities of an ionizable dopant are added to the vapor generated from the LC eluant, allowing for a great abundance of dopant photoions to be produced. Because the ion source is at atmospheric pressure, and the collision rate is high, the dopant photoions react to completion with solvent and analyte molecules present in the ion source. Using APPI, at an LC flow rate of 200 microL/min, it is possible to obtain analyte signal intensities 8 times as high as those obtainable with a commercially available corona discharge-atmospheric pressure chemical ionization source.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Pressure Ionization Mass Spectrometry
Carroll, D. I., Dzidic, I., Horning, E. C., & Stillwell, R. N. (1981) · Applied Spectroscopy Reviews · doi:10.1080/05704928108060409 · Cited by 170
Cited by
Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions
Cody, R. B., Laramée, J. A., & Durst, H. D. (2005) · Analytical Chemistry · doi:10.1021/ac050162j · Cited by 2,483
Chemistry of Atmospheric Brown Carbon
Laskin, A., Laskin, J., & Nizkorodov, S. A. (2015) · Chemical Reviews · doi:10.1021/cr5006167 · Cited by 1,832
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Chemical derivatization and mass spectral libraries in metabolic profiling by GC/MS and LC/MS/MS
Halket, J. M., Waterman, D., Przyborowska, A. M., Patel, R. K. P., Fraser, P. D., & Bramley, P. M. (2005) · Journal of Experimental Botany · doi:10.1093/jxb/eri069 · Cited by 662
Organic coating on biochar explains its nutrient retention and stimulation of soil fertility
Hagemann, N., Joseph, S., Schmidt, H.-P., Kammann, C. I., Harter, J., Borch, T., Young, R. B., Varga, K., Taherymoosavi, S., Elliott, K. W., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01123-0 · Cited by 616
Metadata
- Authors
- Robb, D. B., Covey, T. R., & Bruins, A. P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-07-07
- Volume
- 72
- Issue
- 15
- Pages
- 3653-3659
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W4246307251
- Cited by
- 748
- References
- 1
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.