CoChat

Protein Concentration and Enzyme Digestion on Microbeads for MALDI-TOF Peptide Mass Mapping of Proteins from Dilute Solutions

Doucette, Alan, Craft, David, Li, Liang · 2000 · Analytical Chemistry
Cited by 84

The DOI matches its Crossref record.

Abstract

A method for generating peptide mass maps from dilute protein samples is presented. The method involves the concentration of proteins from aqueous solution by adsorption onto reversed-phase polymeric microbeads. These beads are then washed extensively to remove contaminants, after which the bound proteins are digested with trypsin. Analysis of the digestion products is performed by MALDI-TOF mass spectrometry following direct deposition of the beads on a MALDI target, along with the matrix solution. The procedure is demonstrated using solutions of cytochrome c, lysozyme, and bovine serum albumin. The results of these digests are compared to trypsin digestions of the protein samples without sample preconcentration. Comparative results are also presented for protein solutions contaminated with 2 M NaCl, 2 M urea, or sodium dodecyl sulfate at concentrations up to 0.02%. These results reveal that, with the microbead preconcentration procedure, peptide mass maps can routinely be generated from highly contaminated samples with a protein concentration of only 100 nM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac000176j

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Doucette, A., Craft, D., & Li, L.
Venue
Analytical Chemistry
Published
2000-06-17
Volume
72
Issue
14
Pages
3355-3362
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1969847041
Cited by
84
References
0
FWCI
2.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.