The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Integration of mass spectrometry in analytical biotechnology
Abstract
Mass spectrometry (MS) has become an indispensable tool for peptide and protein structure analysis because of three unique capabilities that enable it to be used to solve structural problems not easily handled by conventional techniques. First, MS is able to provide accurate molecular weight information on low-picomole amounts of peptides and proteins independent of covalent modifications that may be present. Second, this information is obtainable for peptides present in complex mixtures such as those that result from a proteolytic digest of a protein. Third, by using tandem MS, partial to complete sequence information may be obtained for peptides containing up to 25 amino acid residues, even if the peptides are present in mixtures. Sensitivity and speed of the MS-based approaches now equal (and in some cases exceed) that of Edman-based sequence analysis. In this perspective we discuss how MS, tandem high-performance MS, and on-line liquid chromatography/MS using fast atom bombardment or electrospray ionization have been integrated with more conventional techniques in order to increase the accuracy and speed of peptide and protein structure characterization. The expanding role of matrix-assisted laser desorption MS in protein analysis is also described. The unique niche that MS occupies for locating and structurally characterizing posttranslational modifications of proteins is emphasized. Examples chosen from the authors' laboratory illustrate how MS is used to sequence blocked proteins, define N- and C-terminal sequence heterogeneity, locate and correct errors in DNA- and cDNA-deduced protein sequences, identify sites of deamidation, isoaspartyl formation, phosphorylation, oxidation, disulfide bond formation, and glycosylation, and define the structural class of carbohydrate at specific attachment sites in glycoproteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Regulation of the mevalonate pathway
Goldstein, J. L., & Brown, M. S. (1990) · Nature · doi:10.1038/343425a0 · Cited by 5,394
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Misalignment-mediated DNA synthesis errors
Kunkel, T. A. (1990) · Biochemistry · doi:10.1021/bi00487a001 · Cited by 299
Cited by
Carr, S. A., Huddleston, M. J., & Bean, M. F. (1993) · Protein Science · doi:10.1002/pro.5560020207 · Cited by 284
Self-citation
Metadata
- Authors
- Carr, S. A., Hemling, M. E., Bean, M. F., & Roberts, G. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1991-12-15
- Volume
- 63
- Issue
- 24
- Pages
- 2802-2824
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1980712779
- Cited by
- 241
- References
- 4
- FWCI
- 18.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.