The DOI matches its Crossref record.
Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer
Abstract
Amperometric sensors have been developed for hydrogen peroxide, choline, and acetylcholine by immobilization of horseradish peroxidase, (HRP), choline oxidase, and acetylcholinesterase in a cross-linked redox polymer deposited on glassy carbon electrodes. Peroxide sensors, prepared by immobilization of HRP alone, gave detection limits of 10 nM and a linear response up to ca. 1 mM. Coimmobilization of HRP and glucose oxidase was used to establish the feasibility of highly efficient bienzyme sensors at low substrate levels. Replacing glucose oxidase with choline oxidase produced sensors with submicromolar detection limits and a linear response up to 0.8 mM. Addition of acetylcholinesterase to the sensors generated a relatively small response to acetylcholine that demonstrates the feasibility of trienzyme sensors. At low substrate concentrations, no loss in sensitivity during a 1-day experiment was observed. The response times of these sensors are all less than 30 s with 2-s response times achieved in some cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Peroxidase-modified electrodes: Fundamentals and application
Ruzgas, T., Csöregi, E., Emnéus, J., Gorton, L., & Marko-Varga, G. (1996) · Analytica Chimica Acta · doi:10.1016/0003-2670(96)00169-9 · Cited by 522
Biomolecular immobilization on conducting polymers for biosensing applications
Ahuja, T., Mir, I. A., Kumar, D., & Rajesh (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.046 · Cited by 502
Structural and Conformational Stability of Horseradish Peroxidase: Effect of Temperature and pH
Chattopadhyay, K., & Mazumdar, S. (2000) · Biochemistry · doi:10.1021/bi990729o · Cited by 325
Liu, S.-Q., & Ju, H.-X. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00014-3 · Cited by 273
Microvoltammetric techniques and sensors for monitoring neurochemical dynamics in vivo. A review
O'Neill, R. D. (1994) · The Analyst · doi:10.1039/an9941900767 · Cited by 270
Chemical sensing of neurotransmitters
Pradhan, T., Jung, H. S., Jang, J. H., Kim, T. W., Kang, C., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60477b · Cited by 256
In-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178
Metadata
- Authors
- Garguilo, M. G., Nhan Huynh, Proctor, A., & Michael, A. C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1993-03-01
- Volume
- 65
- Issue
- 5
- Pages
- 523-528
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1994487420
- Cited by
- 213
- References
- 0
- FWCI
- 14.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.