Phenyl- and Butyltin Analysis in Small Biological Samples by Cold Methanolic Digestion and GC/MS
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A very efficient technique for the analysis of six butyl- and phenyltin compounds in biota samples has been developed. No special equipment is needed for sample preparation, which is based on cold methanolic digestion with subsequent aqueous ethylation and liquid-liquid extraction. For samples of only 40 mg of biological materials, method detection limits ranging from 4 to 52 ng/g were achieved using gas chromatography/mass spectrometry. Relative recoveries for the individual butyl- and phenyltins, referring to perdeuterated organotin analogues as internal standards, ranged from 96 to 107%. Organotin concentrations in insect larvae (Chironomus riparius) and a reference mussel tissue (CRM 477) were determined with excellent precision (RSD <5%), and the measured butyltins in CRM 477 were in good agreement with the certified values. Comparison with accelerated solvent extraction confirmed high accuracy, and application for a bioconcentration experiment with phenyltins demonstrated the robustness and suitability of the method for routine analyses. The procedure allows fast, reliable, and simple determination of organotin compounds in low-size biological samples, which was demonstrated for bioconcentration experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ecotoxicology of Organotin Compounds
Fent, K. (1996) · Critical Reviews in Toxicology · doi:10.3109/10408449609089891 · Cited by 992
Self-citation
Cited by
Regueiro, J., Llompart, M., Garcia-Jares, C., Garcia-Monteagudo, J. C., & Cela, R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.091 · Cited by 547
Liu, Y., Zhao, E., Zhu, W., Gao, H., & Zhou, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.076 · Cited by 301
Wu, P., He, L., Zheng, C., Hou, X., & Sturgeon, R. E. (2010) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c003483e · Cited by 170
Analytical Applications of Volatile Metal Derivatives
Sturgeon, R. E., & Mester, Z. (2002) · Applied Spectroscopy · doi:10.1366/000370202760249675 · Cited by 168
Sorption and desorption behavior of organotin compounds in sediment−pore water systems
Berg, M., Arnold, C. G., Müller, S. R., Mühlemann, J., & Schwarzenbach, R. P. (2001) · Environmental Science & Technology · doi:10.1021/es010010f · Cited by 99
Self-citation
Metadata
- Authors
- Looser, P. W., Berg, M., Fent, K., Mühlemann, J., & Schwarzenbach, R. P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-09-20
- Volume
- 72
- Issue
- 20
- Pages
- 5136-5141
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2021131713
- Cited by
- 42
- References
- 1
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phenyl- and Butyltin Analysis in Small Biological Samples by Cold Methanolic Digestion and GC/MS. https://app.cochat.ai/papers/10.1021/ac0005520
- The paper
- Looser, P. W., Berg, M., Fent, K., Mühlemann, J., & Schwarzenbach, R. P. (2000). Phenyl- and Butyltin Analysis in Small Biological Samples by Cold Methanolic Digestion and GC/MS. Analytical Chemistry. https://doi.org/10.1021/ac0005520
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.