Predicting Electrospray Response from Chromatographic Retention Time
The DOI matches its Crossref record.
Abstract
The relationship between electrospray ionization response and HPLC retention time was explored. For the series of small peptides studied, higher ESI response was observed for analytes with longer reversed-phase HPLC retention times. This correlation existed for both experimentally measured retention times and those calculated from amino acid retention coefficients. This study is useful to ESI users since it provides a way to predict and understand anomalies in ESI response with a readily accessible experimental parameter (chromatographic retention time). In addition, the ability to correlate ESI response with chromatographic partitioning lends validity to the equilibrium partitioning model, which explains differences in ESI response on the basis of partitioning between the surface and interior phases of the ESI droplet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Self-citationPhosphorylation Analysis by Mass Spectrometry
Steen, H., Jebanathirajah, J. A., Rush, J., Morrice, N., & Kirschner, M. W. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500135-mcp200 · Cited by 349
Proteomics of Integral Membrane ProteinsTheory and Application
Speers, A. E., & Wu, C. C. (2007) · Chemical Reviews · doi:10.1021/cr068286z · Cited by 325
Wang, Y., Fonslow, B. R., Wong, C. C. L., Nakorchevsky, A., & Yates, J. R. (2012) · Analytical Chemistry · doi:10.1021/ac301091m · Cited by 144
Metadata
- Authors
- Cech, N. B., Krone, J. R., & Enke, C. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-12-08
- Volume
- 73
- Issue
- 2
- Pages
- 208-213
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1988547024
- Cited by
- 138
- References
- 0
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predicting Electrospray Response from Chromatographic Retention Time. https://app.cochat.ai/papers/10.1021/ac0006019
- The paper
- Cech, N. B., Krone, J. R., & Enke, C. G. (2001). Predicting Electrospray Response from Chromatographic Retention Time. Analytical Chemistry. https://doi.org/10.1021/ac0006019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.