The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sequence-selective biosensor for DNA based on electroactive hybridization indicators
Abstract
Deoxyribonucleic acid was covalently immobilized onto oxidized glassy carbon electrode surfaces that had been activated using 1-[3-(dimethylamino)-propyl]-3-ethylcarbodimide hydrochloride and N-hydroxysulfosuccinimide. This reaction is selective for immobilization through deoxyguanosine (dG) residues. Immobilized DNA was detected voltammetrically, using tris (2,2'-bipyridyl)cobalt(III) perchlorate and tris (1,10-phenanthroline)cobalt(III) perchlorate (Co(bpy)3(3+) and Co(phen)3(3+). These complexes are reversibly electroactive (1e-) and preconcentrate at the electrode surface through association with double-stranded DNA. Voltammetric peak currents obtained with a poly(dG)poly(dC)-modified electrode depend on [Co(bpy)3(3+)] and [Co(phen)3(3+)] in a nonlinear fashion and indicate saturation binding with immobilized DNA. Voltammetric peak currents for Co(phen)3(3+) reduction were used to estimate the (constant) local DNA concentration at the modified electrode surface; a binding site size of 5 base pairs and an association constant of 1.74 x 10(3) M(-1) yield 8.6 +/- 0.2 mM base pairs. Cyclic voltammetric peak separations indicate that heterogeneous electron transfer is slower at DNA-modified electrodes than at unmodified glassy carbon electrodes. A prototype sequence-selective DNA sensor was constructed by immobilizing a 20-mer oligo (deoxythymidylic acid) (oligo(dT)20), following its enzymatic elongation with dG residues, which yielded the species oligo(dT)20(dG)98. Cyclic voltammograms of 0.12 mM Co(bpy)3(3+) obtained before and after hybridization with poly-(dA) and oligo(dA)20 show increased cathodic peaks after hybridization. The single-stranded form is regenerated on the electrode surface by rinsing with hot deionized water. These results demonstrate the use of electroactive hybridization indicators in a reusable sequence-selective biosensor for DNA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of the Cystic Fibrosis Gene: Cloning and Characterization of Complementary DNA
Riordan, J. R., Rommens, J. M., Kerem, B.-S., Alon, N., Rozmahel, R., Grzelczak, Z., Zielenski, J., Lok, S., Plavsic, N., Chou, J.-L., et al. (1989) · Science · doi:10.1126/science.2475911 · Cited by 7,418
Cited by
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Cutting out the middleman: DNA biosensors based on electrochemical oxidation
Thorp, H. H. (1998) · Trends in Biotechnology · doi:10.1016/s0167-7799(97)01162-1 · Cited by 255
Metadata
- Authors
- Millan, K. M., & Mikkelsen, S. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1993-09-01
- Volume
- 65
- Issue
- 17
- Pages
- 2317-2323
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2042386699
- Cited by
- 552
- References
- 1
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.