The DOI matches its Crossref record.
Development of a Multichannel Microfluidic Analysis System Employing Affinity Capillary Electrophoresis for Immunoassay
Abstract
A six-channel microfluidic immunoassay device with a scanned fluorescence detection system is described. Six independent mixing, reaction, and separation manifolds are integrated within one microfluidic wafer, along with two optical alignment channels. The manifolds are operated simultaneously and data are acquired using a singlepoint fluorescence detector with a galvano-scanner to step between separation channels. A detection limit of 30 pM was obtained for fluorescein with the scanning detector, using a 7.1-Hz sampling rate for each of the reaction manifolds and alignment channels (57-Hz overall sampling rate). Simultaneous direct immunoassays for ovalbumin and for anti-estradiol were performed within the microfluidic device. Mixing, reaction, and separation could be performed within 60 s in all cases and within 30 s under optimized conditions. Simultaneous calibration and analysis could be performed with calibrant in several manifolds and sample in the other manifolds, allowing a complete immunoassay to be run within 30 s. Careful chip conditioning with methanol, water, and 0.1 M NaOH resulted in peak height RSD values of 3-8% (N = 5 or 6), allowing for cross-channel calibration. The limit of detection (LOD) for an anti-estradial assay obtained in any single channel was 4.3 nM. The LOD for the cross-channel calibration was 6.4 nM. Factors influencing chip and detection system design and performance are discussed in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Metadata
- Authors
- Cheng, S. B., Skinner, C. D., Taylor, J., Attiya, S., Lee, W. E., Picelli, G., & Harrison, D. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-03-06
- Volume
- 73
- Issue
- 7
- Pages
- 1472-1479
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2024237260
- Cited by
- 165
- References
- 0
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Multichannel Microfluidic Analysis System Employing Affinity Capillary Electrophoresis for Immunoassay. https://app.cochat.ai/papers/10.1021/ac0007938
- The paper
- Cheng, S. B., Skinner, C. D., Taylor, J., Attiya, S., Lee, W. E., Picelli, G., & Harrison, D. J. (2001). Development of a Multichannel Microfluidic Analysis System Employing Affinity Capillary Electrophoresis for Immunoassay. Analytical Chemistry. https://doi.org/10.1021/ac0007938
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.