The DOI matches its Crossref record.
An Experimental Comparison of the Maximum Likelihood Estimation and Nonlinear Least-Squares Fluorescence Lifetime Analysis of Single Molecules
Abstract
Two procedures based on the weighted least-squares (LS) and the maximum likelihood estimation (MLE) method to confidently analyze single-molecule (SM) fluorescence decays with a total number (N) of 2,500-60,000 counts have been elucidated and experimentally compared by analyzing measured bulk and SM decays. The key observation of this comparison is that the LS systematically underestimates the fluorescence lifetimes by approximately 5%, for the range of 1,000-20,000 events, whereas the MLE method gives stable results over the whole intensity range, even at counts N less than 1,000, where the LS analysis delivers unreasonable values. This difference can be attributed to the different statistics approaches and results from improper weighting of the LS method. As expected from theory, the results of both methods become equivalent above a certain threshold of N detected photons per decay, which is here experimentally determined to be approximately 20,000. In contrast to the bulk lifetime distributions, the SM fluorescence lifetime distributions exhibit standard deviations that are sizably larger than the statistically expected values. This comparison proves the strong influence of the inhomogenuous microenvironment on the photophysical behavior of single molecules embedded in a 10-30-nm thin polymer layer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accurate Single-Molecule FRET Studies Using Multiparameter Fluorescence Detection
Sisamakis, E., Valeri, A., Kalinin, S., Rothwell, P. J., & Seidel, C. A. M. (2010) · Methods in Enzymology · doi:10.1016/s0076-6879(10)75018-7 · Cited by 268
Self-citationSindbert, S., Kalinin, S., Nguyen, H., Kienzler, A., Clima, L., Bannwarth, W., Appel, B., Müller, S., & Seidel, C. A. M. (2011) · Journal of the American Chemical Society · doi:10.1021/ja105725e · Cited by 268
Self-citationSingle-Molecule Fluorescence Spectroscopy of Photosynthetic Systems
Kondo, T., Chen, W. J., & Schlau-Cohen, G. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00195 · Cited by 120
Metadata
- Authors
- Maus, M., Cotlet, M., Hofkens, J., Gensch, T., De Schryver, F. C., Schaffer, J., & Seidel, C. A. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-04-04
- Volume
- 73
- Issue
- 9
- Pages
- 2078-2086
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2092293413
- Cited by
- 258
- References
- 0
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Experimental Comparison of the Maximum Likelihood Estimation and Nonlinear Least-Squares Fluorescence Lifetime Analysis of Single Molecules. https://app.cochat.ai/papers/10.1021/ac000877g
- The paper
- Maus, M., Cotlet, M., Hofkens, J., Gensch, T., De Schryver, F. C., Schaffer, J., & Seidel, C. A. M. (2001). An Experimental Comparison of the Maximum Likelihood Estimation and Nonlinear Least-Squares Fluorescence Lifetime Analysis of Single Molecules. Analytical Chemistry. https://doi.org/10.1021/ac000877g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.