The DOI matches its Crossref record.
Simultaneous Multianalyte Detection with a Nanometer-Scale Pore
Abstract
It was recently shown that naturally occurring, genetically engineered or chemically modified channels can be used to detect analytes in solution. We demonstrate here that the overall range of analytes that can be detected by single nanometer-scale pores is expanded using a potentially simpler system. Instead of attaching recognition elements to a channel, they are covalently linked to polymers that otherwise thread through a nanometer-scale pore. Because the rate of unbound polymer entering the pore is proportional to its concentration in the bulk, the binding of analyte to the polymer alters the latter's ability to thread through the pore, and the signal that results from individual polymer translocation is unique to the polymer type; the method permits multianalyte detection and quantitation. We demonstrate here that two different proteins can be simultaneously detected with this technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DNA molecules and configurations in a solid-state nanopore microscope
Li, J., Gershow, M., Stein, D., Brandin, E., & Golovchenko, J. A. (2003) · Nature Materials · doi:10.1038/nmat965 · Cited by 936
Single-nucleotide discrimination in immobilized DNA oligonucleotides with a biological nanopore
Stoddart, D., Heron, A. J., Mikhailova, E., Maglia, G., & Bayley, H. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0901054106 · Cited by 482
Single-molecule mass spectrometry in solution using a solitary nanopore
Robertson, J. W. F., Rodrigues, C. G., Stanford, V. M., Rubinson, K. A., Krasilnikov, O. V., & Kasianowicz, J. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611085104 · Cited by 364
Self-citationDigitally encoded DNA nanostructures for multiplexed, single-molecule protein sensing with nanopores
Bell, N. A. W., & Keyser, U. F. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.50 · Cited by 345
Translocation of Single-Stranded DNA Through Single-Walled Carbon Nanotubes
Liu, H., He, J., Tang, J., Liu, H., Pang, P., Cao, D., Krstic, P., Joseph, S., Lindsay, S., & Nuckolls, C. (2010) · Science · doi:10.1126/science.1181799 · Cited by 342
Metadata
- Authors
- Kasianowicz, J. J., Henrickson, S. E., Weetall, H. H., & Robertson, B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-04-11
- Volume
- 73
- Issue
- 10
- Pages
- 2268-2272
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2089726088
- Cited by
- 193
- References
- 0
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Multianalyte Detection with a Nanometer-Scale Pore. https://app.cochat.ai/papers/10.1021/ac000958c
- The paper
- Kasianowicz, J. J., Henrickson, S. E., Weetall, H. H., & Robertson, B. (2001). Simultaneous Multianalyte Detection with a Nanometer-Scale Pore. Analytical Chemistry. https://doi.org/10.1021/ac000958c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.