CoChat

A CE−MALDI Interface Based on the Use of Prestructured Sample Supports

Johnson, Torbjörn, Bergquist, Jonas, Ekman, Rolf, Nordhoff, Eckhard, Schürenberg, Martin, Klöppel, Klaus-Dieter, Müller, Martin, Lehrach, Hans, Gobom, Johan · 2001 · Analytical Chemistry
Cited by 73

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We have developed an off-line coupling of capillary electrophoresis (CE) to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF-MS) based on CE fraction collection onto prestructured MALDI sample supports. Analyte carryover and detection sensitivity were investigated using a standard peptide mixture. Low femtomole amounts were detected, and no noticeable carryover was discovered. The performance of the method was evaluated with a mixture of tryptic digests of proteins from a human fetal brain cDNA expression library. The total number of identified peptides was increased from 47 to 211 when the CE-MALDI interface was used compared to direct MALDI-MS analysis. Sequence coverage with CE-MALDI was in the 25-60% range for the different proteins, corresponding to an increase of 1.3-4.9 times relative to that obtained with MALDI-MS of the crude mixture. Fractionation of sample components also facilitated protein identification by MALDI postsource decay analysis. Our initial results suggest this CE-MALDI interface can be used for the analysis of complex peptide mixtures isolated from biological tissues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0011888

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 73

Metadata

Authors
Johnson, T., Bergquist, J., Ekman, R., Nordhoff, E., Schürenberg, M., Klöppel, K.-D., Müller, M., Lehrach, H., & Gobom, J.
Venue
Analytical Chemistry
Published
2001-03-09
Volume
73
Issue
8
Pages
1670-1675
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2071758941
Cited by
73
References
1
FWCI
3.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.