Inductively coupled plasma mass spectrometric detection for multielement flow injection analysis and elemental speciation by reversed-phase liquid chromatography
The DOI matches its Crossref record.
Abstract
The feasibility of using an inductively coupled plasma mass spectrometer as a muitieiement detector for flow injection analysis (FIA) and ion-pair reversed-phase liquid chromatography was investigated. Sample introduction was by uitrasonk nebulization with aerosol desolvation. Absolute detecton limits for FIA ranged from 0.01 to 0.1 ng for most elements using 10-pL injections. Over 30 elements were surveyed for their response to both anionic and cationic ion pairing reagents. The separation and selective detection of various As and Se species were demonstrated, yielding detection limits near 0.1 ng (as element) for ail six species present. Determination of 15 elements in a single injection with multiple ion monitoring produced shniiar detection limits. Isotope ratios were measured with sufficient precision (better than 2%) and accuracy (about 1 %) on eluting peaks of Cd and Pb to demonstrate that liquid chromatographyhductively coupled plasma mass spectrometry should make speciation studies with stable tracer isotopes feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accelerated Solvent Extraction: A Technique for Sample Preparation
Richter, B. E., Jones, B. A., Ezzell, J. L., Porter, N. L., Avdalovic, N., & Pohl, C. (1996) · Analytical Chemistry · doi:10.1021/ac9508199 · Cited by 1,234
Interferences in inductively coupled plasma mass spectrometry. A review
Evans, E. H., & Giglio, J. J. (1993) · Journal of Analytical Atomic Spectrometry · doi:10.1039/ja9930800001 · Cited by 393
Recent advances in flow injection analysis
Trojanowicz, M., & Kołacińska, K. (2016) · The Analyst · doi:10.1039/c5an02522b · Cited by 202
Metadata
- Authors
- Thompson, J. J., & Houk, R. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1986-10-01
- Volume
- 58
- Issue
- 12
- Pages
- 2541-2548
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2064926891
- Cited by
- 211
- References
- 0
- FWCI
- 13.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inductively coupled plasma mass spectrometric detection for multielement flow injection analysis and elemental speciation by reversed-phase liquid chromatography. https://app.cochat.ai/papers/10.1021/ac00125a039
- The paper
- Thompson, J. J., & Houk, R. S. (1986). Inductively coupled plasma mass spectrometric detection for multielement flow injection analysis and elemental speciation by reversed-phase liquid chromatography. Analytical Chemistry. https://doi.org/10.1021/ac00125a039
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.