The DOI matches its Crossref record.
Solid-Phase Microextraction Using Fused-Silica Fibers Coated with Sol−Gel-Derived Hydroxy-Crown Ether
Abstract
A novel solid-phase microextraction (SPME) fiber containing hydroxydibenzo-14-crown-4 (OH-DB14C4)/hydroxy-terminated silicone oil (OH-TSO) was first prepared by a sol-gel method and investigated for the determination of phenols. The possible mechanism is discussed and confirmed by IR spectra. The coating has stable performance in high temperature (to 350 degrees C) and solvents (organic and inorganic) due to the chemical binding between the coating and the fiber surface. The addition of crown ether enhances the polarity of the coating compared with that of the sol-gel OH-terminated silicone oil fiber and, accordingly, provides higher extraction efficiency for polar phenolic compounds. On the other hand, OH-terminated silicone oil in the coating can not only increase the length of network but also help to spread the stationary phase on the silica surface uniformly. The fluorescence microscopy experiment suggests the benefit the more uniform surface of the sol-gel-derived OHDB14C4/OH-TSO fiber in comparison with sol-gelderived OH-DB14C4 fiber. Some parameters of the SPME fiber for the determination of phenols were investigated. Limits of detection of the phenols are below 1.0 ng/mL, and the precisions are from 2.9 to 4.6% (n = 6). Linear ranges were found to be 0.1-10 microg/mL The sensitivity of the method is enhanced at a low-pH level (pH approximately 1) and with the addition of salt. The method was applied to the analysis of wastewater sample from a paper mill.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Properties and applications of proteins encapsulated within sol–gel derived materials
Jin, W., & Brennan, J. D. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)00229-5 · Cited by 499
The sol-gel encapsulation of enzymes
Pierre, A. C. (2004) · Biocatalysis and Biotransformation · doi:10.1080/10242420412331283314 · Cited by 384
Heterogeneous catalysis in continuous flow microreactors: A review of methods and applications
Tanimu, A., Jaenicke, S., & Alhooshani, K. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.06.161 · Cited by 355
Kumar, A., Gaurav, Malik, A. K., Tewary, D. K., & Singh, B. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.01.028 · Cited by 330
Piri-Moghadam, H., Alam, M. N., & Pawliszyn, J. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.05.035 · Cited by 317
Metadata
- Authors
- Zeng, Z., Qiu, W., & Huang, Z.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-04-28
- Volume
- 73
- Issue
- 11
- Pages
- 2429-2436
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2069494428
- Cited by
- 160
- References
- 0
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Solid-Phase Microextraction Using Fused-Silica Fibers Coated with Sol−Gel-Derived Hydroxy-Crown Ether. https://app.cochat.ai/papers/10.1021/ac0012750
- The paper
- Zeng, Z., Qiu, W., & Huang, Z. (2001). Solid-Phase Microextraction Using Fused-Silica Fibers Coated with Sol−Gel-Derived Hydroxy-Crown Ether. Analytical Chemistry. https://doi.org/10.1021/ac0012750
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.