The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fluorescence Quenching as an Indirect Detection Method for Nitrated Explosives
Abstract
A novel approach based on fluorescence quenching is presented for the analysis of nitrated explosives. Seventeen common explosives and their degradation products are shown to be potent quenchers of pyrene, having Stern-Volmer constants that generally increase with the degree of nitration. Aromatic explosives such as 2,4,6-trinitrotoluene (2,4,6-TNT) are more effective quenchers than aliphatic or nitramine explosives. In addition, nitroaromatic explosives are found to have unique interactions with pyrene that lead to a wavelength dependence of their Stern-Volmer constants. This phenomenon allows for their differentiation from other nitrated explosives. The fluorescence quenching method is then applied to the determination of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine(HMX), 2,4,6-TNT, nitromethane, and ammonium nitrate in various commercial explosive samples. The samples are separated by capillary liquid chromatography with post-column addition of the pyrene solution and detection by laser-induced fluorescence. The indirect fluorescence quenching method shows increased sensitivity and selectivity over traditional UV-visible absorbance as well as the ability to detect a wider range of organic and inorganic nitrated compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On a theory of the van der waals adsorption of gases
Brunauer, S., Deming, L. S., Deming, W. E., & Teller, E. (1940) · Journal of the American Chemical Society · doi:10.1021/ja01864a025 · Cited by 4,829
Cited by
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Highly Selective and Sensitive Fluorescent Paper Sensor for Nitroaromatic Explosive Detection
Ma, Y., Li, H., Peng, S., & Wang, L. (2012) · Analytical Chemistry · doi:10.1021/ac302138c · Cited by 283
(2006) · Principles of Fluorescence Spectroscopy · doi:10.1007/978-0-387-46312-4_8 · Cited by 278
Metadata
- Authors
- Goodpaster, J. V., & McGuffin, V. L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-03-23
- Volume
- 73
- Issue
- 9
- Pages
- 2004-2011
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2076670340
- Cited by
- 183
- References
- 1
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence Quenching as an Indirect Detection Method for Nitrated Explosives. https://app.cochat.ai/papers/10.1021/ac001347n
- The paper
- Goodpaster, J. V., & McGuffin, V. L. (2001). Fluorescence Quenching as an Indirect Detection Method for Nitrated Explosives. Analytical Chemistry. https://doi.org/10.1021/ac001347n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.