The DOI matches its Crossref record.
On-Line High-Precision Stable Hydrogen Isotopic Analyses on Nanoliter Water Samples
Abstract
We describe a new on-line chromium reduction technique for the measurement of stable hydrogen (deltaD) isotopes in waters using continuous-flow isotope ratio mass spectrometry. The on-line Cr reduction method has low intersample memory effects (< 1%) and excellent precision and accuracy for deltaD (+/-0.5% and was used to analyze waters samples as small as 50 nL. The on-line Cr method has a number of significant advantages over conventional offline Zn and U reduction and on-line carbon-based pyrolysis techniques. A single Cr reactor can be used to analyze approximately 1,000 water samples using an injection volume of 0.5 microL, with an individual sample analysis time of 4 min. Intersample memory effects are negligible. The Cr reactor temperature of 1050 degree C is easily attainable on standard elemental analyzers and so does not require the specialized and costly high-temperature furnaces of carbon-based pyrolysis reactors. Furthermore, hydrogen isotopes in extremely small water samples in the 100-nL range or less can be easily measured; hence, this new method opens up a number of exciting application areas in earth and environmental sciences, for example, natural abundance deltaD measurements of individual fluid inclusions in geologic materials using a laser source and measurements of body fluids in physiological and metabolic research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A synchronized dating of three Greenland ice cores throughout the Holocene
Vinther, B. M., Clausen, H. B., Johnsen, S. J., Rasmussen, S. O., Andersen, K. K., Buchardt, S. L., Dahl‐Jensen, D., Seierstad, I. K., Siggaard‐Andersen, M. ‐., Steffensen, J. P., et al. (2006) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2005jd006921 · Cited by 670
Defining an absolute reference frame for ‘clumped’ isotope studies of CO2
Dennis, K. J., Affek, H. P., Passey, B. H., Schrag, D. P., & Eiler, J. M. (2011) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2011.09.025 · Cited by 627
Butler, P. J., Green, J. A., Boyd, I. L., & Speakman, J. R. (2004) · Functional Ecology · doi:10.1111/j.0269-8463.2004.00821.x · Cited by 501
High-Precision Laser Spectroscopy D/H and 18O/16O Measurements of Microliter Natural Water Samples
Lis, G., Wassenaar, L. I., & Hendry, M. J. (2008) · Analytical Chemistry · doi:10.1021/ac701716q · Cited by 445
Eggemeyer, K. D., Awada, T., Harvey, F. E., Wedin, D. A., Zhou, X., & Zanner, C. W. (2008) · Tree Physiology · doi:10.1093/treephys/tpn019 · Cited by 268
Metadata
- Authors
- Morrison, J., Brockwell, T., Merren, T., Fourel, F., & Phillips, A. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-06-30
- Volume
- 73
- Issue
- 15
- Pages
- 3570-3575
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2044127701
- Cited by
- 243
- References
- 0
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.