Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 165

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Multivariate determination of glucose in whole blood by attenuated total reflection infrared spectroscopy

Heise, H. M., Marbach, Ralf., Janatsch, Guenter., Kruse-Jarres, J. D. · 1989 · Analytical Chemistry

Abstract

A spectral analysis of whole EDTA blood was undertaken by using attenuated total reflection and Fourier-transform infrared spectroscopy. The concentration of blood glucose was measured by an enzymatic method using glucose dehydrogenase and ranged between 40 and 290 mg/dL with an average concentration of 90.4 mg/dL. Multivariate calibration with the partial least-squares (PLS) algorithm was performed on spectral data between 1500 and 750 cm-1 showing a varying background from different unidentified interfering compounds. Cross validation was carried out for optimizing the PLS model. PRESS was 19.8 mg/dL, which was calculated on the basis of 127 standards, whereas the estimated standard deviation for the calibration fit was computed to be 11.9 mg/dL. Infrared spectroscopy can be used for monitoring glucose levels within the normal physiological range in a complex matrix like whole blood as an alternative to electrochemical sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00193a004

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Heise, H. M., Marbach, R., Janatsch, G., & Kruse-Jarres, J. D.
Venue
Analytical Chemistry
Published
1989-09-15
Volume
61
Issue
18
Pages
2009-2015
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2034249239
Cited by
165
References
1
FWCI
5.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.