The DOI matches its Crossref record.
Surface Biopassivation of Replicated Poly(dimethylsiloxane) Microfluidic Channels and Application to Heterogeneous Immunoreaction with On-Chip Fluorescence Detection
Open accessAbstract
Poly(dimethylsiloxane) (PDMS) appeared recently as a material of choice for rapid and accurate replication of polymer-based microfluidic networks. However, due to its hydrophobicity, the surface strongly interacts with apolar analytes or species containing apolar domains, resulting in significant uncontrolled adsorption on channel walls. This contribution describes the application and characterization of a PDMS surface treatment that considerably decreases adsorption of low and high molecular mass substances to channel walls while maintaining a modest cathodic electroosmotic flow. Channels are modified with a three-layer biotin-neutravidin sandwich coating, made of biotinylated IgG, neutravidin, and biotinylated dextran. By replacing biotinylated dextran with any biotinylated reagent, the modified surface can be readily patterned with biochemical probes, such as antibodies. Combination of probe immobilization chemistry with low nonspecific binding enables affinity binding assays within channel networks. The example of an electrokinetic driven, heterogeneous immunoreaction for human IgG is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,379
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
SERS-Activated Platforms for Immunoassay: Probes, Encoding Methods, and Applications
Wang, Z., Zong, S., Wu, L., Zhu, D., & Cui, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00027 · Cited by 614
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Self-citationVerpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Self-citationLab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
UV/ozone modification of poly(dimethylsiloxane) microfluidic channels
Berdichevsky, Y., Khandurina, J., Guttman, A., & Lo, Y.-H. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2003.09.022 · Cited by 318
Metadata
- Authors
- Linder, V., Verpoorte, E., Thormann, W., de Rooij, N. F., & Sigrist, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-07-27
- Volume
- 73
- Issue
- 17
- Pages
- 4181-4189
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1977803728
- Cited by
- 173
- References
- 0
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.