The DOI matches its Crossref record.
Retention and Separation of Adenosine and Analogues by Affinity Chromatography with an Aptamer Stationary Phase
Abstract
A biotinylated-DNA aptamer (molecular weight 16,600) that binds adenosine and related compounds in solution was immobilized by reaction with streptavidin, which had been covalently attached to porous chromatographic supports. The aptamer medium was packed into fused-silica capillaries (50-150-microm i.d.) to form affinity chromatography columns. Frontal chromatography analysis indicated that the dissociation constants (Kd) of cyclic-AMP, AMP, ATP, ADP, and adenosine were 138 +/- 18, 58 +/- 2, 38 +/- 2, 28 +/- 6 and 3 +/- 1 microM, respectively, for aptamer immobilized on a controlled pore glass support. Similar values were obtained for aptamer immobilized on a polystyrene support except for a slightly higher Kd for adenosine. The Kd for adenosine is similar to the previously reported value of 6 +/- 3 microM for adenosine-aptamer in solution indicating that immobilized aptamers can have affinity similar to that of the solution forms. Columns had 20 nmol of binding sites/100 microL of support media, which is 3.3-fold higher than that previously reported for immobilization of IgG on similar media, indicating that the aptamer can be immobilized with higher density than antibodies. Variation of mobile-phase conditions revealed that ionic strength and Mg2+ level had strong effects on retention of analytes while pH and buffer composition had less of an effect. It was demonstrated that the column could selectively retain and separate cyclic-AMP, NAD+, AMP, ADP, ATP, and adenosine, even in complex mixtures such as tissue extracts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SELEX—A (r)evolutionary method to generate high-affinity nucleic acid ligands
Stoltenburg, R., Reinemann, C., & Strehlitz, B. (2007) · Biomolecular Engineering · doi:10.1016/j.bioeng.2007.06.001 · Cited by 1,430
Analytical applications of aptamers
Tombelli, S., Minunni, M., & Mascini, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.006 · Cited by 1,017
FluMag-SELEX as an advantageous method for DNA aptamer selection
Stoltenburg, R., Reinemann, C., & Strehlitz, B. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3388-9 · Cited by 367
Mirror‐Image Oligonucleotides: History and Emerging Applications
Young, B. E., Kundu, N., & Sczepanski, J. T. (2019) · Chemistry – A European Journal · doi:10.1002/chem.201900149 · Cited by 93
Metadata
- Authors
- Deng, Q., German, I., Buchanan, D., & Kennedy, R. T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-10-19
- Volume
- 73
- Issue
- 22
- Pages
- 5415-5421
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2043872789
- Cited by
- 190
- References
- 0
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.