Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Surface-Enhanced Raman Scattering on Uniform Platinum-Group Overlayers: Preparation by Redox Replacement of Underpotential-Deposited Metals on Gold

Mrozek, Melissa F., Xie, Yong, Weaver, Michael J. · 2001 · Analytical Chemistry

Abstract

The preparation of Pt-group metal films on roughened gold electrodes by utilizing spontaneous redox replacement of an underpotential-deposited (upd) copper or lead monolayer with a Pt-group metal cation solute is described. The resulting films display intense surface-enhanced Raman scattering (SERS) for adsorbates bound to the overlayer and free from substrate interferences. This strategy provides a useful alternative, at least for platinum, to the constant-current electrodeposition method commonly utilized to prepare SERS-active Pt-group metal films (Zou, S.; Weaver, M. J. Anal. Chem. 1988, 70. 2387). Similarly to related earlier studies, the film uniformity (specifically, the absence or otherwise of residual Au "pinhole" sites) was tested by employing carbon monoxide, and also ethylene, as "probe" chemisorbates, since they yield vibrational frequencies on Au that are blue-shifted from the corresponding bands for adsorbate bound to Pt-group metal sites. While a single redox replacement of upd Cu with Pt(IV) yielded incomplete surface coverage, as expected, the use of multiple (up to eight) replacement cycles produced Pt films displaying remarkably intense CO vibrational bands as well as apparently "pinhole-free" properties, although such imperfections were detected with the ethylene probe. A single upd Cu replacement with Pt(II), however, yielded a remarkably uniform Pt layer, as indicated by pinhole-free characteristics using both the CO and ethylene probes along with the voltammetric behavior. The use of additional redox replacement cycles yielded marked progressive attenuation in the SERS signals. Comparable, although less optimal, SERS behavior was obtained for Pd films prepared similarly from Pd(II). The value of the strategy for exploring catalytic as well as equilibrium adsorptive chemistry on Pt surfaces is also illustrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0106391

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 205

Metadata

Authors
Mrozek, M. F., Xie, Y., & Weaver, M. J.
Venue
Analytical Chemistry
Published
2001-11-10
Volume
73
Issue
24
Pages
5953-5960
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2000912325
Cited by
205
References
1
FWCI
5.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.