Liquid-Phase Microextraction of Phenolic Compounds Combined with On-Line Preconcentration by Field-Amplified Sample Injection at Low pH in Micellar Electrokinetic Chromatography
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper describes a novel method that applies field-amplified sample injection (FASI) in micellar electrokinetic chromatography (MEKC) with a low pH background electrolyte (BGE). Six phenolic compounds prepared in water or NaOH solution were used as the test analytes. Sample was injected electrokinetically after the introduction of a plug of water. During the injection, the water plug was pumped out of the capillary inlet by the electroosmotic flow, and the phenolic anions migrated very quickly in the direction of the outlet. When the anions reached the boundary between the water plug and BGE, they were neutralized and ceased moving. Thereafter, MEKC was initiated for the separation. This on-line preconcentration method could be conveniently coupled with a liquid-liquid-liquid microextraction procedure, in which a hollow fiber was used as an extraction solvent support to extract the analytes from the water sample. The acceptor phase consisted of 8 mM NaOH. After extraction, the extract was analyzed directly by MEKC, as described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245
Cited by
Electrokinetic migration across artificial liquid membranes
Pedersen-Bjergaard, S., & Rasmussen, K. E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.01.025 · Cited by 678
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Pedersen-Bjergaard, S., & Rasmussen, K. E. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.088 · Cited by 486
Stacking phenomena in electromigration: From basic principles to practical procedures
Urbánek, M., Křivánková, L., & Boček, P. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200390056 · Cited by 194
Basheer, C., & Lee, H. K. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.09.083 · Cited by 183
Self-citation
Metadata
- Authors
- Zhu, Tu, & Lee, H. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-11-01
- Volume
- 73
- Issue
- 23
- Pages
- 5655-5660
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2054795052
- Cited by
- 64
- References
- 1
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid-Phase Microextraction of Phenolic Compounds Combined with On-Line Preconcentration by Field-Amplified Sample Injection at Low pH in Micellar Electrokinetic Chromatography. https://app.cochat.ai/papers/10.1021/ac0106602
- The paper
- Zhu, Tu, & Lee, H. K. (2001). Liquid-Phase Microextraction of Phenolic Compounds Combined with On-Line Preconcentration by Field-Amplified Sample Injection at Low pH in Micellar Electrokinetic Chromatography. Analytical Chemistry. https://doi.org/10.1021/ac0106602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.