Automatic Identification of Proteins with a MALDI-Quadrupole Ion Trap Mass Spectrometer
The DOI matches its Crossref record.
Abstract
A matrix-assisted laser desorption/ionization (MALDI) ion trap mass spectrometer of new design is described. The instrument is based on a commercial Finnegan LCQ ion trap mass spectrometer to which we have added a MALDI ion source that incorporates a sample stage constructed from a compact disk and a new ion transmission interface. The ion interface contains a quadrupole ion guide installed between the skimmer and the octapoles of the original instrument configuration, allowing for operation in both MALDI and electrospray ionization modes. The instrument has femtomole sensitivity for peptides and is capable of collecting a large number of MALDI MS and MALDI MS/MS spectra within a short period of time. The MALDI source produces reproducible signals for 10(4)-10(5) laser pulses, enabling us to collect MS/MS spectra from all the discernible singly charged ions detected in a MS peptide map. We describe the different modes of the instrument operation and algorithms for data processing as applied to challenging protein identification problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Sequence and Structural Convergence of Broad and Potent HIV Antibodies That Mimic CD4 Binding
Scheid, J. F., Mouquet, H., Ueberheide, B., Diskin, R., Klein, F., Oliveira, T. Y. K., Pietzsch, J., Fenyo, D., Abadir, A., Velinzon, K., et al. (2011) · Science · doi:10.1126/science.1207227 · Cited by 1,139
Self-citationProteomic analysis of the mammalian nuclear pore complex
Cronshaw, J. M., Krutchinsky, A. N., Zhang, W., Chait, B. T., & Matunis, M. J. (2002) · The Journal of Cell Biology · doi:10.1083/jcb.200206106 · Cited by 966
Self-citationProteomic applications for the early detection of cancer
Wulfkuhle, J. D., Liotta, L. A., & Petricoin, E. F. (2003) · Nature Reviews Cancer · doi:10.1038/nrc1043 · Cited by 907
Dou, Y., Milne, T. A., Tackett, A. J., Smith, E. R., Fukuda, A., Wysocka, J., Allis, C. D., Chait, B. T., Hess, J. L., & Roeder, R. G. (2005) · Cell · doi:10.1016/j.cell.2005.04.031 · Cited by 664
Self-citation
Metadata
- Authors
- Krutchinsky, A. N., Kalkum, M., & Chait, B. T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-10-03
- Volume
- 73
- Issue
- 21
- Pages
- 5066-5077
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2089676623
- Cited by
- 144
- References
- 0
- FWCI
- 10.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic Identification of Proteins with a MALDI-Quadrupole Ion Trap Mass Spectrometer. https://app.cochat.ai/papers/10.1021/ac010682o
- The paper
- Krutchinsky, A. N., Kalkum, M., & Chait, B. T. (2001). Automatic Identification of Proteins with a MALDI-Quadrupole Ion Trap Mass Spectrometer. Analytical Chemistry. https://doi.org/10.1021/ac010682o
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.