Ion Parking during Ion/Ion Reactions in Electrodynamic Ion Traps
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Under appropriate ion density conditions, it is possible to selectively inhibit rates of ion/ion reactions in a quadrupole ion trap via the application of oscillatory voltages to one or more electrodes of the ion trap. The phenomenon is demonstrated using dipolar resonance excitation applied to the end-cap electrodes of a three-dimensional quadrupole ion trap. The application of a resonance excitation voltage tuned to inhibit the ion/ion reaction rate of a specific range of ion mass-to-charge ratios is referred to as "ion parking". The bases for rate inhibition are (i) an increase in the relative velocity of the ion/ion reaction pair, which reduces the cross section for ion/ion capture and, at least in some cases, (ii) reduction in the time of physical overlap of positively charged and negatively charged ion clouds. The efficiency and specificity of the ion parking experiment is highly dependent upon ion densities, trapping conditions, ion charge states, and resonance excitation conditions. The ion parking experiment is illustrated herein along with applications to the concentration of ions originally present over a range of charge states into a selected charge state and in the selection of a particular ion from a set of ions derived from a simple protein mixture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ion/Ion Reactions in the Gas Phase: Proton Transfer Reactions Involving Multiply-Charged Proteins
Stephenson, J. L., & McLuckey, S. A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9611755 · Cited by 215
Self-citationIon/Ion Proton Transfer Reactions for Protein Mixture Analysis
Stephenson, J. L., & McLuckey, S. A. (1996) · Analytical Chemistry · doi:10.1021/ac9605657 · Cited by 145
Self-citation
Cited by
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Swaney, D. L., McAlister, G. C., Wirtala, M., Schwartz, J. C., Syka, J. E. P., & Coon, J. J. (2007) · Analytical Chemistry · doi:10.1021/ac061457f · Cited by 363
‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Self-citationTop-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Ion Activation Methods for Peptides and Proteins
Macias, L. A., Santos, I. C., & Brodbelt, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04859 · Cited by 107
Metadata
- Authors
- McLuckey, S. A., Reid, G. E., & Wells, J. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-12-08
- Volume
- 74
- Issue
- 2
- Pages
- 336-346
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1999848785
- Cited by
- 115
- References
- 2
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.