Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 318

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Headspace Solvent Microextraction

Theis, Aaron L., Waldack, Adam J., Hansen, Susan M., Jeannot, Michael A.·2001·Analytical Chemistry

Abstract

A hanging microliter drop of 1-octanol is shown to be an excellent preconcentration medium for headspace analysis of volatile compounds in an aqueous matrix by gas chromatography (GC) or gas chromatography/mass spectrometry (GC/MS). Model compounds benzene, toluene, ethylbenzene, and o-xylene (BTEX) are conveniently and rapidly preconcentrated in the microdrop. An internal standard, decane, is present in the organic extracting solvent, and linear calibration curves of relative peak area versus aqueous concentration are obtained for the four model compounds. Detailed kinetic studies reveal that the overall rate of mass transfer is limited by both the aqueous-phase stirring rate and the degree of convection within the organic phase. The very low vapor pressure of 1-octanol results in minimal evaporation of the microdrop during the extraction time. This system represents an inexpensive, convenient, and precise sample cleanup and preconcentration method for the determination of volatile organic compounds at trace levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac015569c

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 318

Metadata

Authors
Theis, A. L., Waldack, A. J., Hansen, S. M., & Jeannot, M. A.
Venue
Analytical Chemistry
Published
2001-10-30
Volume
73
Issue
23
Pages
5651-5654
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2059601073
Cited by
318
References
1
FWCI
9.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.