Simultaneous Determination of Estrogenic Short Ethoxy Chain Nonylphenols and Their Acidic Metabolites in Water by an In-Sample Derivatization/Solid-Phase Microextraction Method
The DOI matches its Crossref record.
Abstract
An in-sample derivatization headspace solid-phase microextraction method has been developed for the simultaneous determination of nonylphenol, nonylphenol mono- and diethoxylates (NP, NP1EO, NP2EO), and their acidic metabolites (NPlEC, NP2EC) in water. The analytical procedure involves derivatization of NPEOs and NPECs to their methyl ethers--esters with dimethyl sulfate/NaOH and further headspace (HS) solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS) determination. Parameters affecting both derivatization efficiency and headspace SPME procedure, such as the selection of the SPME coating, derivatizationextraction time, temperature and ionic strength were optimized. The commercially available Carbowax-divinylbenzene (CW-DVB) fiber appears to be the most suitable for the simultaneous determination of both NPEOs-NPECs. Run-to-run precision of the in-sample derivatization/HS-SPME-GC/MS method gave relative standard deviations between 8 and 18%. The method was linear for NP over 2 orders of magnitude, and detection limits were compound dependent but ranged from 20 to 1500 ng/L. The SPME procedure was compared with a solid-phase extraction SPE-GC/MS method for the analysis of NPEOs-NPECs in water samples and good agreement was obtained. Therefore, in-sample derivatization HS-SPME-GC/MS can be used as a method for the simultaneous determination of short ethoxy chain nonylphenols and their acidic metabolites in water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Ternes, T. A. (2014) · Analytical Chemistry · doi:10.1021/ac500508t · Cited by 2,144
Solid‐phase microextraction: a powerful sample preparation tool prior to mass spectrometric analysis
Vas, G., & Vékey, K. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.606 · Cited by 615
Chang, H.-S., Choo, K.-H., Lee, B., & Choi, S.-J. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.06.135 · Cited by 377
Gatidou, G., Thomaidis, N. S., Stasinakis, A. S., & Lekkas, T. D. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.037 · Cited by 322
Liu, R., Zhou, J. L., & Wilding, A. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2003.09.035 · Cited by 306
Metadata
- Authors
- Díaz, A., Ventura, F., & Galceran, M. T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-07-04
- Volume
- 74
- Issue
- 15
- Pages
- 3869-3876
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2047497305
- Cited by
- 78
- References
- 0
- FWCI
- 10.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Determination of Estrogenic Short Ethoxy Chain Nonylphenols and Their Acidic Metabolites in Water by an In-Sample Derivatization/Solid-Phase Microextraction Method. https://app.cochat.ai/papers/10.1021/ac020124p
- The paper
- Díaz, A., Ventura, F., & Galceran, M. T. (2002). Simultaneous Determination of Estrogenic Short Ethoxy Chain Nonylphenols and Their Acidic Metabolites in Water by an In-Sample Derivatization/Solid-Phase Microextraction Method. Analytical Chemistry. https://doi.org/10.1021/ac020124p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.