The DOI matches its Crossref record.
Passively Driven Integrated Microfluidic System for Separation of Motile Sperm
Abstract
This paper describes a self-contained integrated microfluidic system that can separate motile sperm from small samples that are difficult to handle using conventional sperm-sorting techniques. The device isolates motile sperm from nonmotile sperm and other cellular debris, based on the ability of motile sperm to cross streamlines in a laminar fluid stream. The device is small, simple, and disposable yet is an integrated system complete with sample inlets, outlets, sorting channel, and a novel passively driven pumping system that provides a steady flow of liquid; it requires no external power source or controls. The device fulfills a need in clinical settings where small amounts of sperm need to be sorted. It also opens the way for convenient bioassays based on sperm motility including at-home motile sperm tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Microfluidics for flow cytometric analysis of cells and particles
Huh, D., Gu, W., Kamotani, Y., Grotberg, J. B., & Takayama, S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/3/r02 · Cited by 396
Self-citationCombined microfluidic-micromagnetic separation of living cells in continuous flow
Xia, N., Hunt, T. P., Mayers, B. T., Alsberg, E., Whitesides, G. M., Westervelt, R. M., & Ingber, D. E. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-0033-0 · Cited by 371
Metadata
- Authors
- Cho, B. S., Schuster, T. G., Zhu, X., Chang, D., Smith, G. D., & Takayama, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-02-22
- Volume
- 75
- Issue
- 7
- Pages
- 1671-1675
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2091904117
- Cited by
- 356
- References
- 0
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Passively Driven Integrated Microfluidic System for Separation of Motile Sperm. https://app.cochat.ai/papers/10.1021/ac020579e
- The paper
- Cho, B. S., Schuster, T. G., Zhu, X., Chang, D., Smith, G. D., & Takayama, S. (2003). Passively Driven Integrated Microfluidic System for Separation of Motile Sperm. Analytical Chemistry. https://doi.org/10.1021/ac020579e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.