Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record.

Sample Filtration, Concentration, and Separation Integrated on Microfluidic Devices

Broyles, B. Scott, Jacobson, Stephen C., Ramsey, J. Michael·2003·Analytical Chemistry

Abstract

Microfabricated devices integrating sample filtration, solid-phase extraction, and chromatographic separation with solvent programming were demonstrated. Filtering of the sample was accomplished at the sample inlet with an array of seven channels each 1 microm deep and 18 microm wide. Sample concentration and separation were performed on channels 5 microm deep and 25 microm wide coated with a C18 phase, and elution was achieved under isocratic, step, or linear gradient conditions. For the solid-phase extraction, signal enhancement factors of 400 over a standard injection of 1.0 s were observed for a 320-s injection. Four polycyclic aromatic compounds were resolved by open channel electrochromatography in under 50 s. Chip operation was unaffected by the presence of the 5-microm silica particles at the filter entrance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac025503x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Broyles, B. S., Jacobson, S. C., & Ramsey, J. M.
Venue
Analytical Chemistry
Published
2003-04-12
Volume
75
Issue
11
Pages
2761-2767
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2050584354
Cited by
174
References
0
FWCI
12.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sample Filtration, Concentration, and Separation Integrated on Microfluidic Devices. https://app.cochat.ai/papers/10.1021/ac025503x
The paper
Broyles, B. S., Jacobson, S. C., & Ramsey, J. M. (2003). Sample Filtration, Concentration, and Separation Integrated on Microfluidic Devices. Analytical Chemistry. https://doi.org/10.1021/ac025503x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.