The DOI matches its Crossref record.
Surface Modification of Poly(dimethylsiloxane) Microfluidic Devices by Ultraviolet Polymer Grafting
Abstract
Poly(dimethylsiloxane) (PDMS)-based microfluidic devices are increasing in popularity due to their ease of fabrication and low costs. Despite this, there is a tremendous need for strategies to rapidly and easily tailor the surface properties of these devices. We demonstrate a one-step procedure to covalently link polymers to the surface of PDMS microchannels by ultraviolet graft polymerization. Acrylic acid, acrylamide, dimethylacrylamide, 2-hydroxylethyl acrylate, and poly(ethylene glycol)monomethoxyl acrylate were grafted onto PDMS to yield hydrophilic surfaces. Water droplets possessed contact angles as low as 45 degrees on the grafted surfaces. Microchannels constructed from the grafted PDMS were readily filled with aqueous solutions in contrast to devices composed of native PDMS. The grafted surfaces also displayed a substantially reduced adsorption of two test peptides compared to that of oxidized PDMS. Microchannels with grafted surfaces exhibited electroosmotic mobilities intermediate to those displayed by native and oxidized PDMS. Unlike the electroosmotic mobility of oxidized PDMS, the electroosmotic mobility of the grafted surfaces remained stable upon exposure to air. The electrophoretic resolution of two test peptides in the grafted microchannels was considerably improved compared to that in microchannels composed of oxidized PDMS. By using the appropriate monomer, it should be possible to use UV grafting to impart a variety of surface properties to PDMS microfluidics devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Biocompatible polymer materials: Role of protein–surface interactions
Chen, H., Yuan, L., Song, W., Wu, Z., & Li, D. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.006 · Cited by 706
Bodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
Developments and new applications of UV-induced surface graft polymerizations
DENG, J., WANG, L., LIU, L., & YANG, W. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.06.002 · Cited by 465
Metadata
- Authors
- Hu, S., Ren, X., Bachman, M., Sims, C. E., Li, G. P., & Allbritton, N.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-06-22
- Volume
- 74
- Issue
- 16
- Pages
- 4117-4123
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2090803851
- Cited by
- 418
- References
- 0
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface Modification of Poly(dimethylsiloxane) Microfluidic Devices by Ultraviolet Polymer Grafting. https://app.cochat.ai/papers/10.1021/ac025700w
- The paper
- Hu, S., Ren, X., Bachman, M., Sims, C. E., Li, G. P., & Allbritton, N. (2002). Surface Modification of Poly(dimethylsiloxane) Microfluidic Devices by Ultraviolet Polymer Grafting. Analytical Chemistry. https://doi.org/10.1021/ac025700w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.