The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrochemical Protein Chip with Arrayed Immunosensors with Antibodies Immobilized in a Plasma-Polymerized Film
Abstract
An electrochemical protein chip was microfabricated. A thin-film three-electrode system, including an array of 36 platinum working electrodes, a set of thin-film Ag/AgCl electrodes, and platinum auxiliary electrodes, was integrated on a glass substrate. Capture antibodies were immobilized in a 4.5-nm-thick double layer of a hexamethyldisiloxane plasma-polymerized film. Because of their highly cross-linked network structure, the capture antibodies could be firmly immobilized. No nonspecific adsorption was observed during a series of procedures to detect target proteins, and electrochemical cross talk between neighboring sites was negligible. The sandwich immunoassay was conducted on a single chip using model proteins, alpha-1-fetoprotein and beta2-microglobulin. A distinct current increase following the oxidation of hydrogen peroxide produced by the enzymatic reaction of glucose oxidase was observed, which indicates that the capture proteins could actually bind the target proteins. Two kinds of protein were detected independently on multiple sites with respective capture antibodies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comprehensive analysis of protein–protein interactions in Saccharomyces cerevisiae
Uetz, P., Giot, L., Cagney, G., Mansfield, T. A., Judson, R. S., Knight, J. R., Lockshon, D., Narayan, V., Srinivasan, M., Pochart, P., et al. (2000) · Nature · doi:10.1038/35001009 · Cited by 4,706
Cited by
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Carbon Nanotube Amplification Strategies for Highly Sensitive Immunodetection of Cancer Biomarkers
Yu, X., Munge, B., Patel, V., Jensen, G., Bhirde, A., Gong, J. D., Kim, S. N., Gillespie, J., Gutkind, J. S., Papadimitrakopoulos, F., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062117e · Cited by 686
Localized Surface Plasmon Resonance Biosensors
Zhao, J., Zhang, X., Yonzon, C. R., Haes, A. J., & Van Duyne, R. P. (2006) · Nanomedicine · doi:10.2217/17435889.1.2.219 · Cited by 508
Metadata
- Authors
- Kojima, K., Hiratsuka, A., Suzuki, H., Yano, K., Ikebukuro, K., & Karube, I.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-01-28
- Volume
- 75
- Issue
- 5
- Pages
- 1116-1122
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1971919913
- Cited by
- 167
- References
- 1
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.