Elemental Fractionation Studies in Laser Ablation Inductively Coupled Plasma Mass Spectrometry on Laser-Induced Brass Aerosols
Abstract
Previous investigations on laser-induced aerosols of brass samples showed that preferential vaporization of zinc occurs during the ablation process leading to elemental fractionation and limited possibilities for non matrix matched calibration. In a variety of experiments carried out within this study it is shown that multiple effects are complicating the quantification of brass using IA-ICPMS. It is shown that the ablated copper and zinc is not homogeneously distributed within the laser-produced aerosol. Copper was found enriched up to 100% in particles larger than 100 nm as shown from EDX measurements (electron excited) on individual particles, and zinc was enriched by over 40% in the particles smaller than the lowest measurable particle size (below 100 nm or in the vapor phase). Solution nebulization analysis on digested filter-collected aerosols results in a higher Cu/Zn ratio than the certified value for the brass sample. ESEM pictures with analysis of the electron excited X-rays measured on the filter-collected material support the results showing copper enrichment. However, online LA-ICPMS measurements carried out under the same operating conditions as for filtering show a copper depletion within the ICP, which leads to the conclusion of partial vaporization and ionization of the aerosol particles in the ICP. The larger particles containing more or exclusively copper are not completely ionized. Within this study, three sources of elemental fractionation can be distinguished and described: (A) The ablation process leads to no measurable copper enrichment at the ablation crater rim. (B) Zinc deposition between the ablation site and the aerosol collection on filters leads to an up to 37% higher Cu/Zn ratio on the filter in comparison to the certified value. (C) On-line laser ablation aerosols measured within the ICPMS lead to significantly lower Cu/Zn ratios in comparison to the certified value. (D) Combination of the various studied sources of fractionation can finally lead to an agreement between measured and certified values due to inverse overlapping of various fractionation sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laser ablation for analytical sampling: what can we learn from modeling?
Bogaerts, A., Chen, Z., Gijbels, R., & Vertes, A. (2003) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2003.08.004 · Cited by 457
Multilayer Paper-Based Device for Colorimetric and Electrochemical Quantification of Metals
Rattanarat, P., Dungchai, W., Cate, D., Volckens, J., Chailapakul, O., & Henry, C. S. (2014) · Analytical Chemistry · doi:10.1021/ac5000224 · Cited by 350
Jakobi, J., Menéndez-Manjón, A., Chakravadhanula, V. S. K., Kienle, L., Wagener, P., & Barcikowski, S. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/14/145601 · Cited by 78
Metadata
- Authors
- Kuhn, H.-R., & Günther, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-01-22
- Volume
- 75
- Issue
- 4
- Pages
- 747-753
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2038688065
- Cited by
- 161
- References
- 0
- FWCI
- 16.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Elemental Fractionation Studies in Laser Ablation Inductively Coupled Plasma Mass Spectrometry on Laser-Induced Brass Aerosols. https://app.cochat.ai/papers/10.1021/ac0259919
- The paper
- Kuhn, H.-R., & Günther, D. (2003). Elemental Fractionation Studies in Laser Ablation Inductively Coupled Plasma Mass Spectrometry on Laser-Induced Brass Aerosols. Analytical Chemistry. https://doi.org/10.1021/ac0259919
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.